Název produktu
Pellicon® XL Cassette Media: Ultracel® 30 kDa, Chemistry: Composite Regenerated Cellulose (CRC) Screen Type: C Device Size: 50 cm²
Quality Segment
material
composite regenerated cellulose (CRC) membrane, polypropylene , polypropylene screen
feature
holdup volume 3.2 mL
manufacturer/tradename
Pellicon®
parameter
0.03–0.05 L/min recirculation rate, 15 mL min. working volume, 2.8 bar max. transmembrane pressure (40 psig), 5.5 bar max. inlet pressure (80 psi) at 50 °C
technique(s)
analytical sample preparation: suitable, protein purification: suitable
L
18.8 cm (7.4 in.)
W
3 cm (1.2 in.)
filtration area
50 cm2
membrane nominal area
50 cm2
gravimetric extractables
≤7.5 mg/device
matrix
Ultracel®
pore size
30 kDa NMWCO
pH
2 –12
shipped in
ambient
General description
Features and Benefits
Packaging
Analysis Note
Other Notes
Legal Information
1 of 1
Tato položka | |||
|---|---|---|---|
| description Chemistry: Composite Regenerated Cellulose (CRC) Screen Type: C Device Size: 50 cm² | description Chemistry: Composite Regenerated Cellulose (CRC) Screen Type: C Device Size: 50 cm² | description Chemistry: Composite Regenerated Cellulose (CRC) Screen Type: C Device Size: 50 cm² | description Chemistry: Composite Regenerated Cellulose (CRC) Screen Type: C Device Size: 50 cm² |
| pore size 30 kDa NMWCO | pore size 5 kDa NMWCO | pore size 300 kDa NMWCO | pore size 10 kDa NMWCO |
| filtration area 50 cm2 | filtration area 50 cm2 | filtration area 50 cm2 | filtration area 50 cm2 |
| technique(s) analytical sample preparation: suitable, protein purification: suitable | technique(s) analytical sample preparation: suitable, protein purification: suitable | technique(s) analytical sample preparation: suitable, protein purification: suitable | technique(s) analytical sample preparation: suitable, protein purification: suitable |
| matrix Ultracel® | matrix Ultracel® | matrix Ultracel® | matrix Ultracel® |
| material composite regenerated cellulose (CRC) membrane, polypropylene screen | material composite regenerated cellulose (CRC) membrane, polypropylene , polypropylene screen | material composite regenerated cellulose (CRC) membrane, polypropylene , polypropylene screen | material composite regenerated cellulose (CRC) membrane, polypropylene , polypropylene screen |
| parameter 0.03–0.05 L/min recirculation rate, 2.8 bar max. transmembrane pressure (40 psig), 15 mL min. working volume, 5.5 bar max. inlet pressure (80 psi) at 50 °C | parameter 0.03-0.05 L/min recirculation rate, 15 mL min. working volume, 2.8 bar max. transmembrane pressure (40 psig), 5.5 bar max. inlet pressure (80 psi) at 50 °C | parameter 0.03–0.05 L/min recirculation rate, 15 mL min. working volume, 2.8 bar max. transmembrane pressure (40 psig), 5.5 bar max. inlet pressure (80 psi) at 50 °C | parameter 0.03-0.05 L/min recirculation rate, 15 mL min. working volume, 2.8 bar max. transmembrane pressure (40 psig), 5.5 bar max. inlet pressure (80 psi) at 50 °C |
Still not finding the right product?
Explore all of our products under Pellicon® XL Cassette Media: Ultracel® 30 kDa
Skladovací třída
12 - Non Combustible Liquids
flash_point_f
Not applicable
flash_point_c
Not applicable
wgk
WGK 2