Vybrat velikost
O této položce
form
liquid
packaging
pkg of 500 mL
manufacturer/tradename
Chemicon®
technique(s)
ELISA: suitable
shipped in
wet ice
General description
Application
Chemicon HRP conjugated antibodies may be diluted up to 1:16,000 in Peroxidase Protective Buffer. Diluted conjugates are stable for at least 3 months when stored at 2 - 8oC. The buffer is suitable for direct use in ELISA. It is recommended that the HRP conjugated antibody is diluted with Peroxidase Protective Buffer and allowed to stand for 24 hours at 2-8°C to attain constant stability before use.
Peroxidase Protective Buffer is compatible with blocking agents such as skim milk powder, Tween 20 and normal serum. However HRP conjugates should not be stored in the presence of these blocking agents. They should be added just prior to use in the assay.
Physical form
Preparation Note
PRECAUTIONS
HRP conjugates should be diluted and stored under clean conditions to reduce the level of microbial challenge.
Sodium azide must NOT be added to Peroxidase Protective Buffer.
Avoid contamination of HRP conjugate solutions with heavy metal ions, aromatic chlorocarbons or hypochlorous acids. Avoid containers made of soda glass or polystyrene. Storage of diluted conjugates in borosilicate glass is recommended.
Efficient washing steps should follow HRP conjugate incubations. In ELISA, at least four thorough wash cycles are recommended.
Legal Information
Disclaimer
Skladovací třída
12 - Non Combustible Liquids
flash_point_f
Not applicable
flash_point_c
Not applicable
Osvědčení o analýze (COA)
Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Související obsah
The Luminata ELISA HRP chemiluminescent substrates provide three major advantages: 1. High sensitivity for detecting as little as 0.1 pg of protein. 2. Broad dynamic detection range (up to 2,500-fold), enabling a wide range of quantitation. 3. Flexibility to adjust signal strength by one of two methods: a. Exposing the well to the luminometer for a longer time. b. Applying a more sensitive substrate to obtain signals in wells with otherwise undetectable signals.
Globální číslo obchodní položky
| Skladová položka | GTIN |
|---|---|
| EPA100 | 04053252678509 |
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis