Saltar al contenido
Merck
Todas las fotos(1)

Key Documents

791649C

Avanti

18:1-d9 SM

Avanti Research - A Croda Brand

Sinónimos:

N-oleoyl(d9)-D-erythro-sphingosylphosphorylcholine

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula empírica (notación de Hill):
C41H72 D9N2O6P
Número de CAS:
Peso molecular:
738.12
UNSPSC Code:
41141825
NACRES:
NA.25

assay

>99% (TLC)

form

liquid

packaging

pkg of 1 × 1 mL (791649C-1mg)

manufacturer/tradename

Avanti Research - A Croda Brand

concentration

1 mg/mL (791649C-1mg)

shipped in

dry ice

storage temp.

−20°C

General description

18:1-d9 SM (N-oleoyl(d9)-D-erythro-sphingosylphosphorylcholine) is a deuterated derivative of 18:1-SM (N-oleoyl-D-erythro-sphingosylphosphorylcholine). 18:1- SM is a sphingomyelin which is present in aqueous humor. 18:1-SM or oleoyl-sphingomyelin, comprises quaternary ammonium group. 18:1-SM or oleoyl-sphingomyelin due to its miscible property is incapable of sequestering with cholesterol-rich domains.
This deuterium labeled lipid is also available in a formulation of multiple lipid standards. The SPLASH LIPIDOMIX Standard includes all of the major lipid classes at ratios relative to human plasma, allowing one easy internal standard solution to be added to every sample.

Application

18:1-d9 SM (N-oleoyl(d9)-D-erythro-sphingosylphosphorylcholine) has been used as an extraction buffer component for lipid isolation from raft and non-raft fractions of synaptic vesicles (SV) from rat brain. It may be used as an internal standard to spike serum lipid extracts for liquid chromatography-mass spectrometry (LC/MS) analysis and ultra-high-performance supercritical fluid chromatography with quadrupole-time-of-flight mass spectrometry (UHPSFC/QTOF-MS) for signal normalization and quantification of pulmonary artery lipids form porcine.

Packaging

5 mL Clear Glass Sealed Ampule (791649C-1mg)

Legal Information

Avanti Research is a trademark of Avanti Polar Lipids, LLC
LIPIDOMIX is a trademark of Avanti Polar Lipids, LLC
SPLASH is a trademark of Avanti Polar Lipids, LLC

pictograms

Skull and crossbonesHealth hazard

signalword

Danger

Hazard Classifications

Acute Tox. 3 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Carc. 2 - Eye Irrit. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 1 - STOT SE 3

target_organs

Central nervous system, Liver,Kidney

Storage Class

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

wgk_germany

WGK 3

flash_point_f

does not flash

flash_point_c

does not flash


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Richard M Epand et al.
Chemistry and physics of lipids, 132(1), 37-46 (2004-11-09)
Sphingomyelin from biological membranes forms segregated domains with cholesterol in fluid bilayers. However, a synthetic form of sphingomyelin with an oleoyl chain linked to sphingosine is not incorporated into cholesterol-rich domains. We have studied the properties of mixtures of oleoyl-sphingomyelin
Alicia Gil-Ramirez et al.
Journal of chromatography. A, 1592, 173-182 (2019-02-03)
Pulmonary artery grafts are needed as cardiovascular bioprosthetics. For successful tissue recellularization after transplantation, lipids have to be removed from the donor artery. Developing a selective process to remove lipids without damaging the extracellular matrix greatly depends on knowing the
Ayman J Aljohani et al.
Molecular vision, 19, 1966-1984 (2013-09-27)
To determine the differential profiles of sphingomyelin, sphingoid base, sphingoid base-1-phosphate and ceramide lipid species and their quantitative differences between control and glaucomatous aqueous humor (AQH) derived from human donors. AQH from control and primary open-angle glaucoma donors was collected
Michael S Gardner et al.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 1118-1119, 137-147 (2019-04-30)
Progress toward better diagnosis and treatment of lipid metabolism-related diseases requires high throughput approaches for multiplexed quantitative analysis of structurally diverse lipids, including phospholipids (PLs). This work demonstrates a simplified "one-pot" phospholipid extraction protocol, as an alternative to conventional liquid-liquid
John Williams et al.
Bioanalysis, 12(3), 143-158 (2020-02-14)
Aim: Very long chain fatty acids (VLCFAs) have been identified as biomarkers for several peroxisomal disorders necessitating the need for reliable biomarker assays in particular C20, C22, C24, C26 in cerebrospinal fluid (CSF). Until now no absolute quantitation assay for

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico