Saltar al contenido
Merck

611905

Sigma-Aldrich

1,4-Dioxane solution

NMR reference standard, 40% in benzene-d6 (99.6 atom % D), chromium(III) acetylacetonate 5 mg/mL, NMR tube size 5 mm × 8 in.

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula empírica (notación de Hill):
C4H8O2
Número de CAS:
Peso molecular:
88.11
MDL number:
UNSPSC Code:
12352005
PubChem Substance ID:
NACRES:
NA.12

grade

NMR reference standard

Quality Level

composition

chromium(III) acetylacetonate, 5 mg/mL

concentration

40% in benzene-d6 (99.6 atom % D)

technique(s)

NMR: suitable

NMR tube size

5 mm × 8 in.

SMILES string

C1COCCO1

InChI

1S/C4H8O2/c1-2-6-4-3-5-1/h1-4H2

Inchi Key

RYHBNJHYFVUHQT-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Features and Benefits

13C sensitivity

Quantity

5 mm O.D. tube contains 0.700 mL.

signalword

Danger

Hazard Classifications

Aquatic Chronic 3 - Asp. Tox. 1 - Carc. 1A - Eye Irrit. 2 - Flam. Liq. 2 - Muta. 1B - Skin Irrit. 2 - STOT RE 1 - STOT SE 3

target_organs

Blood, Respiratory system

supp_hazards

Storage Class

3 - Flammable liquids

wgk_germany

WGK 3

flash_point_f

70.0 °F - closed cup

flash_point_c

21.1 °C - closed cup

ppe

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Naoyuki Kishimoto et al.
Water research, 47(5), 1919-1927 (2013-02-09)
This paper reports on the reusability and the optimal reuse of iron-rich sludge for an electrochemical Fenton-type process using sequencing batch mode and separation batch mode reuse models. In the sequencing batch mode, processes of electrochemical treatment, neutralization, sedimentation, and
O N Makshakova et al.
Bioorganicheskaia khimiia, 38(3), 300-305 (2012-09-25)
Our interest in modifying influence of the low-molecular organic compounds on the hydration shell of biopolymers is due to a well-known fact that the former can act as regulators of the enzymatic activity changed the hydration shell of the latter.
Venkateshwarlu Gurram et al.
Chemistry, an Asian journal, 7(8), 1853-1861 (2012-05-10)
Reaction conditions for the CC cross-coupling of O(6)-alkyl-2-bromo- and 2-chloroinosine derivatives with aryl-, hetaryl-, and alkylboronic acids were studied. Optimization experiments with silyl-protected 2-bromo-O(6)-methylinosine led to the identification of [PdCl(2)(dcpf)]/K(3)PO(4) in 1,4-dioxane as the best conditions for these reactions (dcpf=1,1'-bis(dicyclohexylphosphino)ferrocene).
Megha Aggarwal et al.
PloS one, 7(12), e51288-e51288 (2012-12-20)
The nucleocapsid core interaction with endodomains of glycoproteins plays a critical role in the alphavirus life cycle that is essential to virus budding. Recent cryo-electron microscopy (cryo-EM) studies provide structural insights into key interactions between capsid protein (CP) and trans-membrane
Richard H Anderson et al.
Integrated environmental assessment and management, 8(4), 731-737 (2012-04-12)
Increasing regulatory attention to 1,4-dioxane has prompted the United States Air Force (USAF) to evaluate potential environmental liabilities, primarily associated with legacy contamination, at an enterprise scale. Although accurately quantifying environmental liability is operationally difficult given limited historic environmental monitoring

Artículos

NMR reference standards ensure proper instrument performance. Review key operational parameters for these standards such as pw90, sensitivity, resolution and line shape.

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico