593648
Phytic acid solution
50 % (w/w) in H2O
Sinónimos:
myo-Inositol hexakis(dihydrogen phosphate)
About This Item
Productos recomendados
Quality Level
concentration
50 % (w/w) in H2O
bp
105 °C
density
1.432 g/mL at 25 °C
functional group
phosphate
SMILES string
OP(O)(=O)O[C@@H]1[C@H](OP(O)(O)=O)[C@H](OP(O)(O)=O)[C@@H](OP(O)(O)=O)[C@H](OP(O)(O)=O)[C@H]1OP(O)(O)=O
InChI
1S/C6H18O24P6/c7-31(8,9)25-1-2(26-32(10,11)12)4(28-34(16,17)18)6(30-36(22,23)24)5(29-35(19,20)21)3(1)27-33(13,14)15/h1-6H,(H2,7,8,9)(H2,10,11,12)(H2,13,14,15)(H2,16,17,18)(H2,19,20,21)(H2,22,23,24)/t1-,2-,3-,4+,5-,6-
InChI key
IMQLKJBTEOYOSI-GPIVLXJGSA-N
¿Está buscando productos similares? Visita Guía de comparación de productos
Categorías relacionadas
General description
Application
- Phytic acid in dental applications: A 2024 study explores the effectiveness of phytic acid as an irrigation solution to improve the adhesion and sealing properties of calcium silicate-based cements in endodontic treatments, demonstrating its potential as a chelating agent in dental procedures (Koçak Şahin and Ünal, 2024).
- Phytic acid in energy storage: Phytic acid is utilized to stabilize magnesium metal anodes in battery technology, contributing to the development of more durable and efficient energy storage systems (Wen et al., 2024).
- Phytic acid in battery technology: Another 2024 study incorporates phytic acid in the development of a hydrogel polymer electrolyte and cathode material for rechargeable zinc metal hydrogel batteries, highlighting its role in enhancing the performance and stability of battery systems (Dilwale et al., 2024).
- Phytic acid in strain sensors: Research focuses on the use of a nacre-mimetic structure multifunctional ion-conductive hydrogel, enhanced by phytic acid, for developing high-performance strain sensors with significant implications in wearable technology and robotics (Wang et al., 2024).
signalword
Danger
hcodes
Hazard Classifications
Acute Tox. 4 Oral - Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1
Storage Class
8A - Combustible corrosive hazardous materials
wgk_germany
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Eyeshields, Gloves, type ABEK (EN14387) respirator filter
Elija entre una de las versiones más recientes:
Certificados de análisis (COA)
¿No ve la versión correcta?
Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico