Saltar al contenido
Merck

[Determination of volatile organic compounds in lung cancer cell lines and lung cancer tissue].

Zhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences (2010-06-15)
Yan-jie Hu, Yuan-hua Qiu, En-guo Chen, Ke-jing Ying, Jin Yu, Ping Wang
RESUMEN

To identify the volatile organic compounds (VOCs) in lung cancer tissue and lung cancer cell lines. The lung cancer tissue samples from 18 patients were cultured and 4 lung cell lines (A549, NCI-H446, SK-MES-1, BEAS-2B) were also included in the study. Air samples in the headspace of culture flasks were analyzed for VOCs with solid-phase micro-extraction and gas chromatography-mass spectroscopy technique (SPME-GC/MS). Two kinds of VOCs 2-pentadecanone and nonadecane were detected in lung cancer cell lines A549, NCI-H446 and SK-MES-1. The concentration of 2-pentadecanone were (1.382 + or -0.171) X 10(-5)mg/L, (1.681 + or - 0.190) X 10(-4)mg/L and (2.835 + or - 0.401) X 10(-6)mg/L, respectively; the concentrations of nonadecane were (8.382 + or - 0.606 ) X 10(-6)mg/L, (1.845 + or - 0.130) X 10(-5)mg/L and (6.220 + or - 0.362) X 10(-6)mg/L), respectively. The eicosane was detected in A549 and NCI-H446 with the concentration of (8.313 + or - 1.130) X 10(-6)mg/L and (1.020 + or - 0.141) X 10(-5)mg/L), respectively. All the 3 VOCs were not detected in cell line BEAS-2B. The concentrations of 12 VOCs including decane, 2- pentadecanone, nonadecane and eicosane were high in 18 lung cancer tissue samples; the concentrations of 2-pentadecanone were 5.421 X 10(-6)mg/L-3.621 X 10(-5)mg/L,those of nonadecane were 5.805 X 10(-6)mg/L-1.830 X 10(-5)mg/L, those of eicosane were 2.730 X 10(-6)mg/L-2.343 X 10(-5)mg/L. There were no differences of VOCs levels among patients with different cancer differentiation (P>0.05). The concentration of eicosane in the non-squamous carcinoma was higher than that in squamous carcinoma, the same results were confirmed in the lung cancer cell lines. This study has identified VOCs produced by lung cancer tissue, which may support to use breath test as a complementary noninvasive diagnostic method for lung cancer.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, needle size 24 ga, for use with manual holder
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, needle size 24 ga, StableFlex
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, needle size 23 ga, StableFlex, for use with autosampler
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Filtro SPME Polidimetilsiloxano (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
Filtro SPME Polidimetilsiloxano (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
Filtro SPME Polidimetilsiloxano (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
SPME fiber assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME fiber assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Sigma-Aldrich
Nonadecane, 99%
Supelco
SPME fiber assembly polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
SPME fiber assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
SPME fiber assembly polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
SPME fiber assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
Filtro SPME Polidimetilsiloxano (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
SPME fiber assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
SPME fiber assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
Kit de surtido de fibra SPME StableFlex, for use with manual holder
Supelco
SPME fiber assembly, Carbowax-Polyethylene Glycol (PEG) Coating, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
Kit de surtido de fibra SPME StableFlex, needle size 23 ga, for use with autosampler
Supelco
SPME fiber assortment kit 4, for use with manual holder, size 24 ga
Supelco
SPME fiber assembly polyacrylate (PA), df 85 μm(PA, for use with manual holder, needle size 24 ga