Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
24056
Columna para GC capilar SP®-2560
L × I.D. 100 m × 0.25 mm, df 0.20 μm
Sinónimos:
SP-2560, 100M.20UM.25MM
About This Item
Productos recomendados
Materiales
fused silica
Nivel de calidad
Agency
AOAC® 2012.13,Ce 1-h05,996.06
meets requirements for USP G5
Parámetros
≤25-250 °C temperature (isothermal or programmed)
Valor Beta
313
df
0.20 μm
técnicas
gas chromatography (GC): suitable
L × D.I.
100 m × 0.25 mm
grupo activo de la matriz
Non-bonded; poly(biscyanopropyl siloxane) phase
aplicaciones
agriculture
clinical
food and beverages
tipo de columna
capillary highly polar
¿Está buscando productos similares? Visita Guía de comparación de productos
Descripción general
Código USP: Esta columna cumple los requisitos USP G5.
Fase:
- No ligada
- Poli(biscianopropil siloxano)
- Desde debajo de la temperatura ambiente hasta 250 °C (isotérmica o programada)
Otras notas
Información legal
Aplicación
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Los clientes también vieron
Protocolos
GC Analysis of a 37-Component FAME Mix on SP™-2560, Slower Oven Ramp
A protocol for GC Analysis of a 37-Component FAME Mix on SP™-2560.
AOCS and AOAC methods for determining the trans fatty acid composition of foods by gas chromatography require the use of a highly polar cyanosilicone capillary column to provide the best peak resolution attainable of the numerous geometric (cis & trans) and positional isomers.
Fast GC Analysis of Detailed cis/trans Fatty Acid Methyl Esters (FAMEs) on the 75 m SP™-2560 Capillary Column
Chromatograms
suitable for GCsuitable for GC, application for SPEsuitable for GCsuitable for GC-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 answer-
Helpful?
-
-
How can I determine the shelf life / expiration / retest date of this product?
1 answer-
If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdfHelpful?
-
-
What is the safety temperature for the GC instrument with SP®-2560 Capillary GC Column (P/N: 24056) to turn off without damaging the column?
1 answer-
It is recommended for lowering the temperature of the GC to 35°C or below with gas flow before shutting the instrument off. If the column will not be in use for an extended period, it is recommended to remove it from the GC and place septa or caps on each end.
Helpful?
-