Saltar al contenido
Merck

GF12929744

Titanium

microfoil, disks, 25mm, thinness 0.25μm, specific density 112.6μg/cm2, permanent mylar 3.5μm support, 99.6+%

Sinónimos:

Titanium, TI004600

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula empírica (notación de Hill):
Ti
Número de CAS:
Peso molecular:
47.87
Número MDL:
Código UNSPSC:
12141746
ID de la sustancia en PubChem:
NACRES:
NA.23

Ensayo

99.60%

Formulario

foil

temp. de autoignición

860 °F

fabricante / nombre comercial

Goodfellow 129-297-44

resistividad

42.0 μΩ-cm, 20°C

diám. × grosor

25 mm × 0.25 μm

bp

3287 °C (lit.)

mp

1660 °C (lit.)

densidad

4.5 g/mL at 25 °C (lit.)

cadena SMILES

[Ti]

InChI

1S/Ti

Clave InChI

RTAQQCXQSZGOHL-UHFFFAOYSA-N

Descripción general

For updated SDS information please visit www.goodfellow.com.

Información legal

Product of Goodfellow

Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Si necesita más asistencia, póngase en contacto con Atención al cliente

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Shaoming Yang et al.
Journal of nanoscience and nanotechnology, 14(6), 4292-4296 (2014-04-18)
The structural and functional characterizations of titanium nitride (TiN) advanced ceramic microsprings (CMSs), with a coil diameter of several micrometers and synthesized by chemical vapor deposition (CVD) were investigated by microscopy techniques. The CMSs were sufficiently mechanically elastic for extension
Konstantinos X Michalakis et al.
The Journal of oral implantology, 40(2), 146-152 (2014-05-02)
Dental implants with an internal connection have been designed to establish a better stress distribution when lateral external forces act on the prosthesis and minimize the forces transmitted to the fastening screw. In the present study, 10 externally and 10
Cédric Weber et al.
Proceedings of the National Academy of Sciences of the United States of America, 111(16), 5790-5795 (2014-04-11)
We carry out a first-principles atomistic study of the electronic mechanisms of ligand binding and discrimination in the myoglobin protein. Electronic correlation effects are taken into account using one of the most advanced methods currently available, namely a linear-scaling density
P F Du et al.
Journal of nanoscience and nanotechnology, 14(6), 4164-4169 (2014-04-18)
Novel TiO2 nanoparticles/nanofibers (NPs/NFs) bilayered nano-composite photoanode film for dye-sensitized solar cells (DSSCs) was fabricated through the combination of spin-coating and electrospinning. The NPs and NFs layers have complementary roles. The underlaid spin-coated NPs layer provides the photoanode film with
G He et al.
Cell proliferation, 47(3), 258-266 (2014-04-18)
To improve efficacy of current titanium and its alloys, in bioactivity and speed of osseointegration, of orthopaedic implants. A novel triple-layered functional graded coating, consisting of a porous hydroxyapatite (HA) outermost layer, fluoro-HA (FHA) intermediate layer and titanium oxide (TiO2

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico