Saltar al contenido
Merck

435139

Sigma-Aldrich

Poly(Bisphenol A carbonate)

melt index 10-12 g/10 min (300°C/1.2kg)

Sinónimos:

2,2-Bis(4-hydroxyphenyl)propane-carbonic acid copolymer, Bisphenol A carbonate polymer, Bisphenol A polycarbonate, Poly(bisphenol A carbonate), Poly(dian carbonate)

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Número de CAS:
MDL number:
UNSPSC Code:
12162002
PubChem Substance ID:
NACRES:
NA.23

form

pellets

melt index

10-12 g/10 min (300°C/1.2kg)

impact strength

801 J/m (Izod, ASTM D 256, 22.7 °C)

dielectric constant

2.96, 1 MHz (ASTM D 150)

hardness

118 (Rockwell R, ASTM D 785)

refractive index

n20/D 1.586

transition temp

softening point 154 °C (Vicat, rate B, ASTM D 1525)

density

1.2 g/mL at 25 °C (lit.)

SMILES string

CC(C)(c1ccc(O)cc1)c2ccc(O)cc2

InChI

1S/C15H16O2.CH2O3/c1-15(2,11-3-7-13(16)8-4-11)12-5-9-14(17)10-6-12;2-1(3)4/h3-10,16-17H,1-2H3;(H2,2,3,4)

InChI key

XSXWYGABGYBZRM-UHFFFAOYSA-N

Gene Information

mouse ... Esr1(13982)
rat ... Ar(24208)

¿Está buscando productos similares? Visita Guía de comparación de productos

General description

Service temperature, max.135°C

Storage Class

11 - Combustible Solids

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Brian T Schaefer et al.
Nature communications, 11(1), 4163-4163 (2020-08-21)
Solid-state magnetic field sensors are important for applications in commercial electronics and fundamental materials research. Most magnetic field sensors function in a limited range of temperature and magnetic field, but Hall sensors in principle operate over a broad range of
M Yalon et al.
Journal of cataract and refractive surgery, 14(4), 393-395 (1988-07-01)
Bisphenol-A polycarbonate has been investigated as an improved polymer for ocular implants, especially for intraocular lenses (IOLs). Polycarbonate properties afford special opportunities for development of tougher, stronger, one-piece IOLs. Autoclave or gamma sterilizability and a higher refractive index may provide
M Utz et al.
Journal of magnetic resonance (San Diego, Calif. : 1997), 128(2), 217-227 (1997-11-14)
A method is proposed for the quantitative measurement of orientational anisotropy in glassy solids based on 2D dipolar NMR spectra with sample flipping (dipolar DECODER experiment). Purely dipolar spectra are obtained by chemical shift refocusing by a multiple pulse sequence.
L Feenstra et al.
Clinical otolaryngology and allied sciences, 9(4), 215-220 (1984-08-01)
A review is given of the development of the concept of an artificial tympanic membrane. Starting with homologous tympanic membranes we compared biodegradable collagen materials (homologous and heterologous) and biodegradable synthetic materials, poly-glycolic acid, poly-lactic acid and poly-alpha-amino acids. As
Yuki Kitahara et al.
Chemosphere, 80(11), 1281-1284 (2010-07-16)
The thermal decomposition of poly(bisphenol A carbonate) (PoC) results in the formation of the endocrine disruptor bisphenol A (BPA). In the present work, we investigated the kinetics of the thermal decomposition of PoC, and the subsequent decomposition of BPA, under

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico