254282

Sigma-Aldrich

Lithium metaborate

99.995% trace metals basis

Sinónimos:

Boric acid lithium salt

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula lineal:
LiBO2
Número de CAS:
Peso molecular:
49.75
EC Number:
MDL number:
UNSPSC Code:
12352302
PubChem Substance ID:
NACRES:
NA.23

assay

99.995% trace metals basis

form

powder

impurities

≤55.0 ppm Trace Metal Analysis

mp

845 °C (lit.)

SMILES string

[Li+].[O-]B=O

InChI

1S/BO2.Li/c2-1-3;/q-1;+1

InChI key

HZRMTWQRDMYLNW-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

signalword

Danger

Hazard Classifications

Acute Tox. 4 Oral - Eye Dam. 1 - Repr. 2

Storage Class

13 - Non Combustible Solids

wgk_germany

WGK 1

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

S Miljanić et al.
Radiation protection dosimetry, 119(1-4), 191-196 (2006-05-20)
Recently, two new types of 'tissue equivalent' thermoluminescent detectors (TLDs) have aroused attention: LiF:Mg,Cu,Na,Si and Li2B4O7:Cu,Ag,P. In this work the characteristics of both detectors were compared with the characteristics of the well-known type LiF:Mg,Ti detector, TLD-100. The following properties were
Thomas Hermanns et al.
The Journal of urology, 185(6), 2241-2247 (2011-04-19)
Technical modifications of the 120 W lithium-triborate laser have been implemented to increase power output, and prevent laser fiber degradation and loss of power output during laser vaporization of the prostate. However, visible alterations at the fiber tip and the
M Ceretti et al.
Radiation protection dosimetry, 144(1-4), 262-265 (2011-02-08)
This work summarises the results of a series of experiences made on Panasonic UD-802AS, a multi-element dosemeter that is currently used in Caorso Nuclear Power Plant for personnel external monitoring. Two main topics have been considered: energy response and the
Jing-lin You et al.
Guang pu xue yu guang pu fen xi = Guang pu, 22(5), 787-789 (2003-08-27)
Raman spectra of xCaSiO3.LiBO2 (by weight ratio, x = 0, 0.25, 0.33, 0.50) crystals were measured. The microstructure of different silicon-oxygen tetrahedrons and their abundant variations with silica contents were studied. It shows that all the silicon-oxygen tetrahedrons are isolated
R Bojanowski et al.
TheScientificWorldJournal, 2, 1891-1905 (2003-08-16)
A simple and rapid method has been developed to determine 226Ra in rocks, soils, and sediments. Samples are decomposed by fusion with lithium metaborate and the melt is dissolved in a solution containing sulfates and citric acid. During the dissolution

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico