50484

Sigma-Aldrich

Methylene Blue solution

suitable for microbiology

Synonyme(s) :

Loeffler’s Methylene Blue

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule empirique (notation de Hill):
C16H18ClN3S
Numéro CAS:
Poids moléculaire :
319.85
Numéro Beilstein :
3641570
Numéro MDL:
Code UNSPSC :
12171500
ID de substance PubChem :
Nomenclature NACRES :
NA.47

Durée de conservation

limited shelf life, expiry date on the label

Concentration

0.5% in H2O (0.5 g/100 mL)

Technique(s)

microbe id | staining: suitable

Application(s)

microbiology

Adéquation

Bacillus spp.
Corynebacterium spp.
bacteria

Chaîne SMILES 

[Cl-].CN(C)c1ccc2N=C3C=C\C(C=C3Sc2c1)=[N+](/C)C

InChI

1S/C16H18N3S.ClH/c1-18(2)11-5-7-13-15(9-11)20-16-10-12(19(3)4)6-8-14(16)17-13;/h5-10H,1-4H3;1H/q+1;/p-1

Clé InChI

CXKWCBBOMKCUKX-UHFFFAOYSA-M

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Methylene Blue was earlier recognized as a good nuclear stain, the staining solutions are always either aged or alkalized, if not both. More importantly it is an excellent stain for ribonucleic acid, which is the important stainable constituent of bacterial bodies, of lymphocyte and hemoportoal cytoplasm, and of nerve cell tigroid granules. It can also be employed in capsule stain. The capsule stain begins as a negative stain leaving the organisms colorless. The capsule are clearly seen as halo surrounding the bacterial cell. Another staining procedure is performed with nigrosin (Cat. No. 43925).

Composants

reagent contains:
methylene blue 0.5 g
distilled water 100 ml

Remplacé(e)(s) par

Code de la classe de stockage

12 - Non Combustible Liquids

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable

Équipement de protection individuelle

Eyeshields, Gloves


Choose from one of the most recent versions:

Certificats d'analyse (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Marcel Gehrung et al.
Journal of biomedical optics, 24(12), 1-11 (2019-10-19)
Photoacoustic tomography (PAT) is intrinsically sensitive to blood oxygen saturation (sO2) in vivo. However, making accurate sO2 measurements without knowledge of tissue- and instrumentation-related correction factors is extremely challenging. We have developed a low-cost flow phantom to facilitate validation of
Nicolaas Lucius Gerlach et al.
Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons, 72(4), 666-671 (2014-02-01)
To establish the accuracy of cone-beam computed tomographic (CBCT) views in determining the position and diameter of the mandibular canal. Two freshly frozen cadaver heads, 1 dentate and 1 edentate, were used to acquire CBCT scans. Measurements on cross-sectional CBCT
Q R J G Tummers et al.
European journal of surgical oncology : the journal of the European Society of Surgical Oncology and the British Association of Surgical Oncology, 40(7), 850-858 (2014-05-28)
Despite recent developments in preoperative breast cancer imaging, intraoperative localization of tumor tissue can be challenging, resulting in tumor-positive resection margins during breast conserving surgery. Based on certain physicochemical similarities between Technetium((99m)Tc)-sestamibi (MIBI), an SPECT radiodiagnostic with a sensitivity of
Muhannad N Fadhel et al.
Journal of biomedical optics, 24(11), 1-8 (2019-11-11)
Solid tumors are typically supplied nutrients by a network of irregular blood vessels. By targeting these vascular networks, it might be possible to hinder cancer growth and metastasis. Vascular disrupting agents induce intertumoral hemorrhaging, making photoacoustic (PA) imaging well positioned
Jonel Steffen et al.
The British journal of ophthalmology, 98(1), 13-15 (2013-10-26)
To evaluate the diagnostic accuracy of methylene blue used as a non-invasive in vivo stain to detect ocular surface squamous neoplasia (OSSN). A test validation study was performed according to Standards for the reporting of diagnostic accuracy studies (STARD) guidelines

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique