F-047
Flubromazolam solution
1.0 mg/mL in methanol, certified reference material, ampule of 1 mL, Cerilliant®
About This Item
Produits recommandés
Qualité
certified reference material
Niveau de qualité
Forme
liquid
Caractéristiques
Snap-N-Spike®/Snap-N-Shoot®
Conditionnement
ampule of 1 mL
Fabricant/nom de marque
Cerilliant®
Concentration
1.0 mg/mL in methanol
Technique(s)
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
Application(s)
clinical testing
Format
single component solution
Température de stockage
−20°C
InChI
1S/C17H12BrFN4/c1-10-21-22-16-9-20-17(12-4-2-3-5-14(12)19)13-8-11(18)6-7-15(13)23(10)16/h2-8H,9H2,1H3
Clé InChI
VXGSZBZQCBNUIP-UHFFFAOYSA-N
Catégories apparentées
Description générale
Flubromazolam, a psychoactive compound, is a triazole analog of the designer benzodiazepine, flubromazepam.
Application
- Residue analysis of nine designer benzodiazepines (DBZDs) in serum samples after their liquid-liquid extraction by non-aqueous capillary electrophoresis coupled with tandem mass spectrometry(MS/MS)
- Simultaneous determination of 11 designer benzodiazepines from urine samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
- Ultra high-performance liquid chromatography-time-of-flight mass spectrometry (UHPLC-TOF-MS) method based separation and quantification of designer benzodiazepines from serum samples following their liquid-liquid extraction
- Combination of parallel artificial liquid membrane extraction (PALME) with UHPLC-MS/MS to determine benzodiazepines, designer benzodiazepines, and z-hypnotics from whole blood samples
- Urine analysis for the testing of 28 designer benzodiazepines reversed phase-LC combined with high-resolution mass spectrometry (HRMS)
Caractéristiques et avantages
- Fully characterized under ISO/IEC 17025 and ISO 17034 accreditation
- Accompanied with a comprehensive Certificate of Analysis (CoA) with data on stability, homogeneity, accuracy of concentration, uncertainty, and traceability
- Rigorously tested through real-time stability studies to ensure accuracy and shelf life
- Gravimetrically prepared using qualified precision balances to ensure minimal uncertainty
- Flame sealed under argon into ampoules for long-term shelf life
- Offered in a convenient, DEA-exempt format to improve laboratory efficiency
Informations légales
Produit(s) apparenté(s)
Mention d'avertissement
Danger
Mentions de danger
Conseils de prudence
Classification des risques
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
Organes cibles
Eyes
Code de la classe de stockage
3 - Flammable liquids
Classe de danger pour l'eau (WGK)
WGK 2
Point d'éclair (°F)
49.5 °F - closed cup
Point d'éclair (°C)
9.7 °C - closed cup
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique