Passa al contenuto
Merck
Tutte le immagini(3)

Documenti fondamentali

93000

Sigma-Aldrich

Trityl chloride

purum, ≥97.0% (HPLC), ≥97.0% (AT)

Sinonimo/i:

Chlorotriphenylmethane, Triphenylchloromethane, Triphenylmethyl chloride

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali

Scegli un formato

100 G
CHF 46.00
500 G
CHF 218.00
5 KG
CHF 1’380.00

CHF 46.00


Spedizione prevista il23 maggio 2025


Richiedi un ordine bulk

Scegli un formato

Cambia visualizzazione
100 G
CHF 46.00
500 G
CHF 218.00
5 KG
CHF 1’380.00

About This Item

Formula condensata:
(C6H5)3CCl
Numero CAS:
Peso molecolare:
278.78
Beilstein:
397363
Numero CE:
Numero MDL:
Codice UNSPSC:
12352101
ID PubChem:
NACRES:
NA.22

CHF 46.00


Spedizione prevista il23 maggio 2025


Richiedi un ordine bulk

Grado

purum

Livello qualitativo

Saggio

≥97.0% (AT)
≥97.0% (HPLC)

Stato

powder

Residuo alla calcinazione

≤0.2% (as SO4)

P. ebollizione

230-235 °C/20 mmHg (lit.)

Punto di fusione

109-112 °C (lit.)
109-113 °C

Solubilità

chloroform: 0.1 g/mL, clear

Gruppo funzionale

chloro
phenyl

Stringa SMILE

ClC(c1ccccc1)(c2ccccc2)c3ccccc3

InChI

1S/C19H15Cl/c20-19(16-10-4-1-5-11-16,17-12-6-2-7-13-17)18-14-8-3-9-15-18/h1-15H
JBWKIWSBJXDJDT-UHFFFAOYSA-N

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Applicazioni

  • Organic Synthesis: Research on the synthesis of 1, 2, 4-triazine derivatives, exploring the condensation reactions of trityl chloride with various compounds (Majid et al., 2020).

Altre note

Reagent for tritylations;; Efficient method of tritylation of sensitive compounds and their subsequent detritylation[1][2]

Pittogrammi

Corrosion

Avvertenze

Danger

Indicazioni di pericolo

Classi di pericolo

Skin Corr. 1B

Codice della classe di stoccaggio

8A - Combustible corrosive hazardous materials

Classe di pericolosità dell'acqua (WGK)

WGK 3

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable

Dispositivi di protezione individuale

Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

I clienti hanno visto anche

Slide 1 of 3

1 of 3

Acqua HPLC Plus

Sigma-Aldrich

34877

Acqua

Acetone HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%

Sigma-Aldrich

650501

Acetone

J S Davidson et al.
Biochimica et biophysica acta, 847(1), 1-7 (1985-10-30)
Intercellular junctional communication was measured using [14C]citrulline incorporation in co-cultures of argininosuccinate synthetase-deficient and argininosuccinate lyase-deficient human fibroblasts. Triphenylmethane, triphenylmethylchloride and tetraphenylboron inhibited communication at concentrations at least 12-fold lower than cytotoxic concentrations. This inhibition was of rapid onset and
Ryuichi Hasegawa et al.
Congenital anomalies, 45(4), 137-145 (2005-12-20)
To elucidate the comparative susceptibility of newborn rats to chemicals, newborn and young animals were administered six industrial chemicals by gavage from postnatal days (PND) 4 to 21, and for 28 days starting at 5-6 weeks of age respectively, under
R Hasegawa et al.
Regulatory toxicology and pharmacology : RTP, 47(3), 296-307 (2006-12-13)
We comprehensively re-analyzed the toxicity data for 18 industrial chemicals from repeated oral exposures in newborn and young rats, which were previously published. Two new toxicity endpoints specific to this comparative analysis were identified, the first, the presumed no observed
K. Barlos et al.
The Journal of Organic Chemistry, 47, 1324-1324 (1982)
Vijayavitthal T Mathad et al.
Natural product research, 20(12), 1053-1058 (2006-11-28)
Jones oxidation of Andrographolide (1), gave mixture of three products (3-dehydroandrographolide (5), 3,19-bis dehydroandrographolide (6) and 19-dehydroandrographolide (7). Tritylation of andrographolide at C19-OH resulted to products 8 and diene 9, which can be converted to its acetate 10 and oxidation

Articoli

Forensic laboratories routinely use STR genotyping for identity testing of biological samples. However, forensic samples often contain low copy numbers of target DNA, making it difficult to obtain complete STR profiles.

Questions

Reviews

No rating value

Active Filters

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.