Passa al contenuto
Merck
Tutte le immagini(1)

Documenti

SCT281

Sigma-Aldrich

BioTracker Blue Live Cell Cycle Assay Solution

Human

Sinonimo/i:

cell cycle dye, cell cycle indicator, cell cycle probe, live cell probe

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
41106514
NACRES:
NA.47

product name

BioTracker Blue Live Cell Cycle Assay Solution,

Origine biologica

human

Livello qualitativo

Confezionamento

vial of 50 tests

Produttore/marchio commerciale

Millipore

tecniche

cell culture | stem cell: suitable
flow cytometry: suitable

Condizioni di spedizione

dry ice

Temperatura di conservazione

−20°C

Descrizione generale

Propidium iodide (PI) is often used for cell cycle analysis by flow cytometry. Compared to this analysis method, the BioTracker Far Red Live Cell Cycle Assay Solution does not require cell fixation or permeabilization, and is permeable in live cells. Use 5 uL of probe solution in 500 uL for each sample. Vial contains enough for 50 tests.IMPORTANT APPLICATION NOTES:*Wash cells thoroughly to remove trypsin. Residual trypsin can confound analysis of flow cytometry populations.*Adjust gates after cells are stained with probe SPECTRAL PROPERTIESExcitation: 405 - 407 nmEmission: 450/50 BPUse violet laser for excitation.

Caratteristiche e vantaggi

Blue fluorescence probe for analysis of the cell cycle by flow cytometry.

Descrizione del bersaglio

The control mechanism of the cell cycle is closely linked to cell proliferation. The cell cycle includes cell division, in which one cell produces two daughter cells. The cell cycle can be assessed by detecting cells stained for DNA using flow cytometry, followed by analysis of the proportion of stained nuclei in cell cycle phase. The cell cycle is classified into two major phases: interphase and the mitotic (M) phase. Interphase is composed of G1 phase (preparation for DNA synthesis which occurs prior to cell division), S phase (DNA synthesis and replication), and G2 phase (chromosome duplication). M phase involves mitosis and cytokinesis. Cell cycle progression is regulated by cyclins and cyclin-dependent kinases. To determine the action of drugs such as anticancer therapeutics, it is essential to analyze the mechanism of cell-cycle checkpoint.

Stoccaggio e stabilità

Store BioTracker Blue Live Cell Cycle Assay Solution at -20 °C, protected from light.

Altre note

Live cell probe for fluorescent cell cycle analysis. Unlike propidium iodide (PI), this probe is membrane permeable and highly specific for DNA, which makes it possible to analyze the cell cycle by simply adding the reagent to a cell suspension without any fixation, permeabilization, or other sample prep.

Note legali

BioTracker is a trademark of Merck KGaA, Darmstadt, Germany

Esclusione di responsabilità

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Pittogrammi

CorrosionEnvironment

Avvertenze

Danger

Indicazioni di pericolo

Classi di pericolo

Aquatic Chronic 2 - Eye Dam. 1

Codice della classe di stoccaggio

12 - Non Combustible Liquids

Classe di pericolosità dell'acqua (WGK)

WGK 3

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.