Passa al contenuto
Merck

Vai a

MPGL06CB1

Millipak® 60 Capsule Media: Durapore® 0.22 µm

Chemistry: Hydrophilic Polyvinylidene Fluoride (PVDF) Inlet: 1/4 in. NPT Outlet: 1/4 in. Hose Barb

Sinonimo/i:

Millipak-60 Filling Machine Filter Unit 0.22 m 1/4 in. NPT-1/4 in.HB, Durapore® 0.22 µm, Millipak® Capsule

Autenticati per visualizzare i prezzi organizzativi e contrattuali.

Scegli un formato

Cambia visualizzazione
A voi/SKUDisponibilitàPrezzo

Informazioni su questo articolo

UNSPSC Code:
23151806
NACRES:
NB.24
eCl@ss:
32031690
Prezzi e disponibilità al momento non sono disponibili
Servizio Tecnico
Hai bisogno di aiuto? Il nostro team di scienziati qualificati è a tua disposizione.
Permettici di aiutarti


Nome del prodotto

Capsula Millipak® con filtro Durapore® da 0,22 µm, Chemistry: Hydrophilic Polyvinylidene Fluoride (PVDF) Inlet: 1/4 in. NPT Outlet: 1/4 in. Hose Barb

Quality Segment

material

PVDF membrane, PVDF vent cap, polycarbonate support, polycarbonate housing

sterility

non-sterile

sterilization compatibility

gamma compatible
x-ray compatible

product line

Millipak®

feature

hydrophilic

manufacturer/tradename

Durapore®

parameter

0.35 bar max. differential pressure (5 psid) at 123 °C (Forward), 0.7 bar max. differential pressure (10 psid) at 25 °C (Reverse), 1.7 bar max. differential pressure (25 psid) at 80 °C (Forward), 4.1 bar max. differential pressure (60 psid) at 25 °C (Forward)

technique(s)

sterile filtration: suitable

filter diam.

7.6 cm (3.0 in.)

filtration area

300 cm2

inlet connection diam.

1/4 in.

outlet connection diam.

1/4 in.

impurities

<0.5  EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

gravimetric extractables

≤2 mg/device

matrix

Durapore®

pore size

0.22 μm

bubble point

≥3450 mbar (50 psig), air with water at 23 °C

fitting

6 mm (1/4 in.) NPT, 6 mm (1/4 in.) outlet hose barb

shipped in

ambient

General description

Device Configuration: Capsule
Number of stacked discs: 60 discs

Packaging

Double Easy-Open bag

Preparation Note

Sterilization Method
3 autoclave cycles of 90 min @ 123°C; not in-line steam sterilizable
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Analysis Note

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Gravimetric Extractables: after 24 hours in water at controlled room temperature
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥200 mL

Other Notes

Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIPAK is a registered trademark of Merck KGaA, Darmstadt, Germany

Confronta articoli simili

Visualizza il confronto per intero

Mostra le differenze

1 of 1

Questo articolo
MPGL06CL1MPGL06CF3MPSL06CL1
pore size

0.22 μm

pore size

0.22 μm

pore size

0.22 μm

pore size

5.0 μm pore size

filtration area

300 cm2

filtration area

300 cm2

filtration area

300 cm2

filtration area

300 cm2

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

technique(s)

prefiltration: suitable

product line

Millipak®

product line

Millipak®

product line

Millipak®

product line

Millipak® 60

matrix

Durapore®

matrix

Durapore®

matrix

Durapore®

matrix

Durapore®

material

PVDF membrane, polycarbonate housing, PVDF vent cap, polycarbonate support

material

PVDF membrane, PVDF vent cap, polycarbonate , polycarbonate support

material

PVDF membrane, PVDF vent cap, polycarbonate housing, polycarbonate support

material

PVDF membrane, PVDF vent cap, polycarbonate , polycarbonate support


Still not finding the right product?




Mantenere la conformità alle GMP utilizzando il programma Emprove®.

Accelerate la qualificazione, mantenete la conformità e risparmiate tempo con Emprove® Dossiers.

Scarica Dossiers

Nota: verrete portati su EmproveSuite.com. Il vostro nome utente e la vostra password sono separati da SigmaAldrich.com e possono essere diversi.

Registrati gratuitamente e accedi a Emprove® Dossiers in pochi minuti. Aggiornate il vostro piano di abbonamento per sbloccare contenuti avanzati e personalizzati nella Emprove® Suite.

Non trovate quello che state cercando? Visitate la pagina di aiuto del programma Emprove®..

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti



Questions

Reviews

No rating value