Passa al contenuto
Merck
Tutte le immagini(1)

Documenti fondamentali

739553

Sigma-Aldrich

Poly(styrene-block-methyl methacrylate)

average Mn 32,000, block ratio of 2:1

Sinonimo/i:

PS-PMMA, block copolymer, Poly(b-methyl methacrylate-polystyrene), PS-block-PMMA, PS-PMMA

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Numero CAS:
Codice UNSPSC:
12162002

Stato

solid

PM

average Mn 10,000 (PMMA)
average Mn 22,000 (polystyrene)
average Mn 32,000

Temp. transizione

Tm 351-356 °C

Mw/Mn

<1.2

InChI

1S/C8H8.C5H8O2/c1-2-8-6-4-3-5-7-8;1-4(2)5(6)7-3/h2-7H,1H2;1H2,2-3H3
ADFPJHOAARPYLP-UHFFFAOYSA-N

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Descrizione generale

22 kDa PS; 10 kDa PMMA; m ~200; n ~100

Pittogrammi

Exclamation mark

Avvertenze

Warning

Indicazioni di pericolo

Consigli di prudenza

Classi di pericolo

Eye Irrit. 2

Codice della classe di stoccaggio

13 - Non Combustible Solids

Classe di pericolosità dell'acqua (WGK)

WGK 3

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Novel fabrication of 2D and 3D inverted opals and their application.
Jae Ah Lee et al.
Small (Weinheim an der Bergstrasse, Germany), 7(18), 2581-2586 (2011-08-03)
F N K Kwong et al.
The Journal of bone and joint surgery. British volume, 88(1), 120-122 (2005-12-21)
The outcome of a cemented hip arthroplasty is partly dependent on the type of cement which is used. The production of an interface gap between the stem and the cement mantle as a result of shrinkage of the cement, may
S J Breusch et al.
Acta orthopaedica Scandinavica, 72(1), 29-35 (2001-05-01)
In a cadaver study, we prepared 29 paired human cadaver femora using 3 different broaches of identical geometry but different surface characteristics. In one group of 20 pairs, preparation with chipped-toothed broaches was compared to diamond-shaped broaches; in the other
M H Geiger et al.
Clinical orthopaedics and related research, (382)(382), 258-266 (2001-01-12)
This controlled study compared the strength and porosity of 48 polymethylmethacrylate cement-implant constructs prepared with open bowl versus vacuum mix technique. Forty-eight blast finished stainless steel rods of 13 mm diameter were implanted with centralizers into 17-mm inner diameter tubes
G J Sterling et al.
The Journal of bone and joint surgery. British volume, 85(5), 646-649 (2003-08-02)
We prospectively investigated a consecutive series of ten patients undergoing a cemented primary total hip replacement (THR) for osteoarthritis in order to establish the elution characteristics of Simplex-tobramycin bone cement (Howmedica, Limerick, Ireland). Specimens of blood, urine and drainage fluid

Questions

Reviews

No rating value

Active Filters

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.