Passa al contenuto
Merck
Tutte le immagini(1)

Documenti fondamentali

356891

Sigma-Aldrich

Cobalt

foil, thickness 1.0 mm, 99.95% trace metals basis

Sinonimo/i:

Cobalt element, Cobalt-59

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali

Scegli un formato

6.25 CM2
CHF 284.00

CHF 284.00


Check Cart for Availability

Richiedi un ordine bulk

Scegli un formato

Cambia visualizzazione
6.25 CM2
CHF 284.00

About This Item

Formula empirica (notazione di Hill):
Co
Numero CAS:
Peso molecolare:
58.93
Numero CE:
Numero MDL:
Codice UNSPSC:
12141710
ID PubChem:
NACRES:
NA.23

CHF 284.00


Check Cart for Availability

Richiedi un ordine bulk

Livello qualitativo

Saggio

99.95% trace metals basis

Stato

foil

Resistività

6.24 μΩ-cm, 20°C

Spessore

1.0 mm

P. ebollizione

2900 °C (lit.)

Densità

8.9 g/mL at 25 °C (lit.)

Stringa SMILE

[Co]

InChI

1S/Co
GUTLYIVDDKVIGB-UHFFFAOYSA-N

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Quantità

25 × 25 mm (approximately 5.6 g)
50 × 50 mm (approximately 22.4 g)

Pittogrammi

Health hazardExclamation mark

Avvertenze

Danger

Classi di pericolo

Acute Tox. 4 Oral - Aquatic Chronic 3 - Carc. 1B - Eye Irrit. 2 - Muta. 2 - Repr. 1A - Resp. Sens. 1 - Skin Sens. 1

Codice della classe di stoccaggio

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

Classe di pericolosità dell'acqua (WGK)

WGK 3

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable

Dispositivi di protezione individuale

dust mask type N95 (US), Eyeshields, Faceshields, Gloves


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

I clienti hanno visto anche

Slide 1 of 6

1 of 6

Cobalt powder, <150 μm, ≥99.9% trace metals basis

Sigma-Aldrich

266647

Cobalt

Cobalt powder, 2 μm particle size, 99.8% trace metals basis

Sigma-Aldrich

266639

Cobalt

Tungsten foil, thickness 0.5 mm, ≥99.9% trace metals basis

Sigma-Aldrich

357189

Tungsten

Silver colloidal, 65-75% Ag basis

Sigma-Aldrich

85131

Silver

Takuya Kurahashi et al.
Inorganic chemistry, 52(7), 3908-3919 (2013-03-23)
The Co(salen)(X) complex, where salen is chiral N,N'-bis(3,5-di-tert-butylsalicylidene)-1,2-cyclohexanediamine and X is an external axial ligand, has been widely utilized as a versatile catalyst. The Co(salen)(X) complex is a stable solid that has been conventionally described as a Co(III)(salen)(X) complex. Recent
D W Su et al.
Journal of nanoscience and nanotechnology, 13(5), 3354-3359 (2013-07-19)
Highly ordered mesoporous Co3O4 nanostructures were prepared using SBA-15 silica as hard templates. The mesoporous structures were characterized by X-ray diffraction, high resolution transmission electron microscopy, and N2 adsorption/desorption isotherm analysis. The results demonstrated that the as-prepared mesoporous Co3O4 has
Pushya A Potnis et al.
Cellular immunology, 282(1), 53-65 (2013-05-18)
Metal orthopedic implant debris-induced osteolysis of hip bone is a major problem in patients with prosthetic-hips. Although macrophages are the principal targets for implant-wear debris, the receptor(s) and mechanisms underlying these responses are not fully elucidated. We examined whether the
H John Cooper et al.
The Journal of bone and joint surgery. American volume, 95(10), 865-872 (2013-05-17)
Femoral stems with dual-taper modularity were introduced to allow additional options for hip-center restoration independent of femoral fixation in total hip arthroplasty. Despite the increasing availability and use of these femoral stems, concerns exist about potential complications arising from the
Jeannette Ø Penny et al.
Acta orthopaedica, 84(2), 130-137 (2013-04-20)
Wear particles from metal-on-metal arthroplasties are under suspicion for adverse effects both locally and systemically, and the DePuy ASR Hip Resurfacing System (RHA) has above-average failure rates. We compared lymphocyte counts in RHA and total hip arthroplasty (THA) and investigated

Articoli

Biomedical implants are essentially foreign substances within the human body that must survive many years’ exposure to demanding mechanical and physiological conditions. Despite these challenges, metal implants have been widely used to substitute for or rebuild hard tissues such as bones and teeth.

Questions

Reviews

No rating value

Active Filters

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.