327492
Platinum
wire, diam. 1.0 mm, 99.9% trace metals basis
Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali
About This Item
Prodotti consigliati
Saggio
99.9% trace metals basis
Forma fisica
wire
Resistività
10.6 μΩ-cm, 20°C
Diametro
1.0 mm
P. eboll.
3827 °C (lit.)
Punto di fusione
1772 °C (lit.)
Densità
21.45 g/cm3 (lit.)
Stringa SMILE
[Pt]
InChI
1S/Pt
BASFCYQUMIYNBI-UHFFFAOYSA-N
Categorie correlate
Descrizione generale
This platinum wire is a thin cylindrical rod of platinum with a diameter of 1 mm. Platinum is a dense, silver-white metal that is highly resistant to corrosion and has a high melting point. Platinum is a precious metal that is valued for its rarity, chemical stability, and catalytic properties. Platinum wire is often used as electrodes in fuel cells, batteries, and other electrochemical devices, in catalytic converters in the automotive industry, in medical implants, and in heating elements and thermocouples.
Applicazioni
Platinum wire may be used as an electrode during various electrochemical studies. It may also be used during the solid state deposition colorless transparent crystals of a new noncentrosymmetric hexaborate, KBOC, on it surface. Platinum wire, as a catalyst may be useful in accelerating the generation of hydrogen from Ni-rich magnesium alloy in NaCl solution.
Quantità
520 mg = 30 mm; 2.6 g = 150 mm
Codice della classe di stoccaggio
13 - Non Combustible Solids
Classe di pericolosità dell'acqua (WGK)
nwg
Punto d’infiammabilità (°F)
Not applicable
Punto d’infiammabilità (°C)
Not applicable
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
I clienti hanno visto anche
K3B6O10Cl: a new structure analogous to perovskite with a large second harmonic generation response and deep UV absorption edge
Journal of the American Chemical Society, 133(20), 7786-7790 (2011)
Wire-like charge transport at near constant bridge energy through fluorene oligomers.
Proceedings of the National Academy of Sciences of the USA, 102(10), 3540-3545 (2005)
Evaluation of a new hydrogen generating system: Ni-rich magnesium alloy catalyzed by platinum wire in sodium chloride solution.
Materials Transactions, 46(12), 2704-2708 (2005)
K3B6O10Cl: a new structure analogous to perovskite with a large second harmonic generation response and deep UV absorption edge.
Journal of the American Chemical Society, 133(20), 7786-7790 (2011)
Japanese journal of clinical oncology, 43(6), 664-668 (2013-04-16)
Interstitial lung disease associated with gefitinib is a critical adverse reaction. When geftinib was administered to EGFR-unknown patients, the interstitial lung disease incidence rate was approximately 3-4% in Japan, and usually occurs during the first 4 weeks of treatment. However
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.