Passa al contenuto
Merck
Tutte le immagini(1)

Documenti fondamentali

240508

Sigma-Aldrich

1,1,2-Trichlorotrifluoroethane

anhydrous, 99.8%

Sinonimo/i:

1,1,2-Trichloro-1,2,2-trifluoroethane, 1,1,2-Trichloro-trifluoroethane, Genetron® 113

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Formula condensata:
ClCF2CCl2F
Numero CAS:
Peso molecolare:
187.38
Beilstein:
1740335
Numero CE:
Numero MDL:
Codice UNSPSC:
12352101
ID PubChem:
NACRES:
NA.21
Prezzi e disponibilità al momento non sono disponibili

Grado

anhydrous

Densità del vapore

2.39 (vs air)

Tensione di vapore

18.81 psi ( 55 °C)
5.5 psi ( 20 °C)
5.69 psi ( 20 °C)

Saggio

99.8%

Stato

liquid

Temp. autoaccensione

1256 °F

Impurezze

<0.002% water
<0.005% water (100 mL pkg)

Residuo dopo evaporazione

<0.0005%

Indice di rifrazione

n20/D 1.358 (lit.)

P. ebollizione

47-48 °C (lit.)

Punto di fusione

−35 °C (lit.)

Densità

1.57 g/mL at 25 °C (lit.)

Stringa SMILE

FC(F)(Cl)C(F)(Cl)Cl

InChI

1S/C2Cl3F3/c3-1(4,6)2(5,7)8
AJDIZQLSFPQPEY-UHFFFAOYSA-N

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Confezionamento

Packaged under nitrogen in Sure/Seal bottles

Note legali

Genetron is a registered trademark of Honeywell International Inc.
Sure/Seal is a trademark of Sigma-Aldrich Co. LLC

Pittogrammi

Exclamation markEnvironment

Avvertenze

Warning

Indicazioni di pericolo

Classi di pericolo

Aquatic Chronic 2 - Eye Irrit. 2 - Ozone 1

Codice della classe di stoccaggio

10 - Combustible liquids

Classe di pericolosità dell'acqua (WGK)

WGK 2

Punto d’infiammabilità (°F)

383.0 °F

Punto d’infiammabilità (°C)

195 °C

Dispositivi di protezione individuale

Eyeshields, Gloves, multi-purpose combination respirator cartridge (US)


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

T Kawakami et al.
Toxicology and industrial health, 6(3-4), 493-498 (1990-05-01)
The interaction of Freon 113 (1,1,2-trichloro-1,2,2-trifluoroethane) and hypoxia on the heart conduction system was studied using electrocardiogram monitoring of isolated perfused rat hearts. Freon 113 (0.2 mM) alone elicited significant atrioventricular conduction delay (p less than 0.05) and heart rate
M Neghab et al.
International archives of occupational and environmental health, 70(3), 187-194 (1997-01-01)
The objectives of this study were threefold. First, to examine the hepatic effects of occupational exposure to 1,1,2-trichloro-1,2,2-trifluoroethane (FC 113) using conventional and newer tests (serum bile acids) of hepatobiliary function. Second, to assess the effects of altered work practices
H K Xiao et al.
American Industrial Hygiene Association journal, 51(7), 395-401 (1990-07-01)
Results obtained using the Fourier transform infrared spectrophotometer (FTIR) and the Miniature Infrared Analyzer (MIRAN) for samples of workplace air containing trichloroethylene (TCE) were evaluated through comparison with results obtained when using a gas chromatography (GC). The effects of instrument
Chieh-Heng Wang et al.
Journal of chromatography. A, 1217(3), 353-358 (2009-12-08)
A gas chromatographic system was constructed to simultaneously measure ambient non-methane hydrocarbons (NMHCs) and halocarbons, which play significant roles in tropospheric ozone formation and stratospheric ozone loss, respectively. A heart-cut device based on a Deans switch was connected to two
T R Auton et al.
International archives of occupational and environmental health, 63(2), 133-138 (1991-01-01)
A physiologically based mathematical model is described for the human inhalation pharmacokinetics of 1,1,2-trichloro-1,2,2-trifluoroethane (FC113). Physiological parameters for the model are derived from the scientific literature. Partition coefficients are determined from in vitro measurements. Predictions of the resulting model for

Questions

Reviews

No rating value

Active Filters

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.