Accéder au contenu
Merck
Toutes les photos(1)

Principaux documents

57281-U

Supelco

SPME LC Fiber Probe, C18

df 45 μm(C18, pkg of 5 ea

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41115724
Nomenclature NACRES :
NB.21

Matériaux

metal alloy fiber
plain red hub

Taille de l'aiguille

22 ga

Conditionnement

pkg of 5 ea

df

45 μm (C18)

Technique(s)

solid phase microextraction (SPME): suitable

L de l'aiguille

25 mm (1 in.)

Groupe de la matrice active

C18 coating

Application(s)

food and beverages

Compatibilité

for use with solvent desorption

Technique de séparation

reversed phase

Description générale

The SPME-LC fiber probes are intended as single-use devices for the extraction of small molecules out of a fluid followed by solvent desorption and LC analysis.

Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

Si vous avez besoin d'assistance, veuillez contacter Service Clients

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Les clients ont également consulté

Xu Zhang et al.
Journal of chromatography. A, 1216(45), 7664-7669 (2009-09-22)
Solid-phase microextraction (SPME) has been demonstrated to be useful for in vivo sampling in pharmacokinetic studies. In this study, a single time-point kinetic calibration for in vivo dynamic monitoring was developed by simplification of the laborious multiple time-point kinetic calibration
Hiroyuki Kataoka et al.
Journal of pharmaceutical and biomedical analysis, 54(5), 926-950 (2011-01-05)
Biomedical analyses of drugs, metabolites, poisons, environmental and occupational pollutants, disease biomarkers and endogenous substances in body fluids and tissues are important in the development of new drugs, therapeutic monitoring, forensic toxicology, patient diagnosis, and biomonitoring of human exposure to
Joanne Chung Yan Yeung et al.
Analytica chimica acta, 665(2), 160-166 (2010-04-27)
The success of in vivo solid phase microextraction (SPME) depends significantly on the selection of calibration method. Three kinetic in vivo SPME calibration methods are evaluated in this paper: (1) on-fibre standardization (OFS), (2) dominant pre-equilibrium desorption (DPED), and (3)
Dajana Vuckovic et al.
Journal of chromatography. A, 1217(25), 4041-4060 (2009-12-25)
The primary objective of this review is to discuss recent technological developments in the field of solid-phase microextraction that have enhanced the utility of this sample preparation technique in the field of bioanalysis. These developments include introduction of various new
Metabolic Profiling of Plasma from Cardiac Surgical Patients Concurrently Administered with Tranexamic Acid: DI-SPME?LC?MS Analysis
Bojko, B., et al.
Journal of Pharmaceutical Analysis, 4 (1), 6-13 (2014)

Articles

Biocompatible SPME devices employ C18 bonded porous silica sorbent particles, in a binder which resists fouling by biological matrix components

Accurate protein binding affinities were measured using bioSPME more rapidly than membrane dialysis (RED) techniques. Binding affinities correlated to the reference values.

Contenu apparenté

A demonstration of the use of innovative BioSPME fibers for the selective extraction of drugs and polar metbolites from biological matrices.

Questions

Reviews

No rating value

Active Filters

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique