GE17-5179-01
Mono Q® 4.6/100 PE
About This Item
Produits recommandés
ligand
-OCH2CH(OH)CH2OCH2CH(OH)CH2N+(CH3)3
Matériaux
PEEK column
Description
Ion Exchanger Type (value)
Conditionnement
pkg of 1 ea
Paramètres
580 psi
Volume du lit
1.7 mL
D.I. de la colonne
4.6 mm
Matrice
monodisperse porous polystyrene/divinyl benzene beads
polymeric
Groupe de la matrice active
ammonium ion, quaternary phase
Taille moy. des particules
10 μm
cleaning
1-14
working range
2-12
Technique de séparation
anion exchange
Description générale
The Tricorn columns offer high-resolution separations with greater loading capacity but slightly lower resolution than MiniBeads columns.
Caractéristiques et avantages
- Monodisperse 10 μm porous beads yield high resolution, dynamic capacity, reproducibility, and durability.
- Maximum resolution is achieved from the efficiency of small, perfectly spherical monodispersed particles optimally packed in columns coupled with the excellent selectivities of the Q ion exchangers.
- Compatible with AKTA design, FPLC™ System, and other high-performance LC systems.
- MonoBeads are also available as Mono P® for chromatofocusing
Stockage et stabilité
Remarque sur l'analyse
Informations légales
Mention d'avertissement
Warning
Mentions de danger
Conseils de prudence
Code de la classe de stockage
3 - Flammable liquids
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Articles
This page shows volatile and non-volatile buffer suggestions for anion and cation exchange chromatography.
This page covers the standard ÄKTAdesign configurations for simple IEX chromatography.
This page covers practical problems that may lead to a non-ideal IEX separation and their solutions.
This page covers detailed aspects of each step in an IEX separation to improve resolution and overall performance.
Protocoles
This page covers using Monobeads for purification of proteins, peptides, or oligonucleotides.
This page shows how to perform column packing and preparation for ion exchange chromatography and chromatafocusing when using Tricorn or XK columns available from Cytiva.
This page clarifies sample preparation, buffer exchange and desalting, removal of lipoproteins, phenol red, and low molecular weight contaminants in Ion exchange chromatography.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique