The Amicon Ultra products are suitable for use with samples containing up to 10% DMSO and 10% DMF. Exposure to 100% DMSO is not recommended. Unfortunately, the compatibility of these devices with 100% DMF has not been determined.
UFC5003
Filtre à centrifuger Amicon® Ultra, seuil de coupure nominal de 3 kDa
sample volume 0.5 mL, regenerated cellulose membrane, MWCO 3 kDa
Synonyme(s) :
Concentrateur centrifuge, seuil de coupure de 3 kDa, volume d'échantillon de 0,5 ml
Sélectionner une taille de conditionnement
Sélectionner une taille de conditionnement
About This Item
Produits recommandés
Matériaux
polypropylene cap
polypropylene tube
regenerated cellulose membrane
styrene-butadiene housing
Niveau de qualité
Stérilité
non-sterile
Gamme de produits
Amicon®
Fabricant/nom de marque
Amicon® Ultra
Paramètres
0.5 mL sample volume
Technique(s)
protein extraction: suitable
protein purification: suitable
Longueur
4.99 cm (1.96 in.)
Diamètre
10.8 mm
Surface de filtration
1 cm2
Volume
0.5 mL
Dimension de pores
3 kDa MWCO
Conditions d'expédition
ambient
Description générale
Leur configuration verticale et leur surface utile de filtration en font des dispositifs très performants : traitement rapide, très bon taux de récupération (en général plus de 90 % de la solution de départ diluée) et possibilité de concentrer l'échantillon 30 ×. Leur configuration verticale permet en outre de minimiser la polarisation du soluté, et donc, le colmatage de la membrane qui en découle. Enfin, la présence d'une butée physique à l'intérieur du dispositif empêche d'atteindre la siccité et prévient les éventuelles pertes d'échantillon. Une étape de centrifugation inverse facile à mettre en œuvre permet de récupérer efficacement l'échantillon concentré (espèces retenues) après le recueil du filtrat.
Les dispositifs Amicon® Ultra de 0,5 ml sont livrés non stériles et sont à usage unique. Grâce à leur membrane verticale et à la centrifugation inverse, les filtres Amicon® Ultra de 0,5 ml offrent d'excellentes performances ainsi que des temps de centrifugation réduits.
Application
- Ultrafiltration sur membrane Ultracel® à seuil de coupure de 3 000 Da
- Concentration d'échantillons biologiques contenant des antigènes, des anticorps, des enzymes, des acides nucléiques ou des micro-organismes
- Purification des composants macromoléculaires présents dans des extraits de culture tissulaire ou des lysats cellulaires, élimination des amorces, élimination des linkers ou marqueurs macromoléculaires d'un mélange réactionnel, et élimination des protéines avant chromatographie liquide haute performance
- Dessalage, échange de tampon et dialyse des protéines
Caractéristiques et avantages
- Membrane Ultracel® en cellulose régénérée à seuil de coupure nominal de 3 kDa offrant une récupération du rétentat supérieure à 90 %
- Concentration de 500 μl en 15 μl
- Facteur de concentration de 25 × à 30 ×
- Très bonne récupération de l'échantillon (plus de 90 % de la solution de départ diluée)
- Traitement rapide : 10 à 30 minutes
- Possibilité de centrifugation inverse pour assurer l'uniformité des taux de récupération
Forme physique
Informations légales
Vous ne trouvez pas le bon produit ?
Essayez notre Outil de sélection de produits.
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Articles
Commercially available protein labeling kits provide researchers with the flexibility to customize their own immunoassay detection panels.
Protein purification is simpler with Amicon Pro. The device delivers consistent sample preparation for more reliable recovery, uncompromised purity and easier data generation.
Filtration methods and membrane filter selection in nanoparticle purification and production.
Méthodes de filtration et sélection d'un filtre membrane pour la purification et la production de nanoparticules.
Protocoles
If an antibody must be purified from a small sample volume (0.5-10 mL), then the Amicon® Pro Purification System is recommended.
Detergents are frequently used to solubilize proteins and nucleic acids during purification, but the presence of detergents may interfere with downstream analyses.
Contenu apparenté
Concentrate protein, don’t lose it. Recover protein reliably when you concentrate with Amicon® Ultra filters.
-
Is this product compatible with organic solvents, such as DMSO or DMF?
1 answer-
Helpful?
-
-
Can I order the filter only, coming with no tube part?
1 answer-
Unfortunately, no, this product is not available as a stand alone item. The tubes are available separately under the product UFC50VL96.
Helpful?
-
-
Is the 0.5 ml 3KDa Amicon device (UFC5003) compatible with a solution containing 5% SDS (Sodium Dodecyl Sulfate)?
1 answer-
The Amicon® Ultra centrifugal devices are designed for processing biological fluids and aqueous solutions. Amicon® Ultra Filter Devices are compatible with concentrations of Sodium dodecyl sulfate (SDS)of 0.1% or less. Prior to use, it is important to verify the chemical compatibility of the sample with the device.
Helpful?
-
-
Hi, Do these filters come with expiry dates? If so where would I be able to find them on the product?
1 answer-
This product is not assigned an expiration date or recommended retest date. Products with no expiration date or recommended retest date should be routinely inspected by customers to ensure they perform as expected. These products are also subject to a one year warranty from the date of shipment. For more information you may access the "Product Dating Information" document under "ADDITIONAL USEFUL DOCUMENTS ABOUT OUR PRODUCTS" at the bottom of the Quality Services page with this link: https://www.sigmaaldrich.com/life-science/quality-and-regulatory-management/quality-services.
Helpful?
-
-
How long should I centrifugate at 14.000 g and how long for the reverse spin at 1000 g?
1 answer-
Typical concentration time for the 3kD membrane device is approximately 30 minutes. However, spin times may need to be adjusted to either a shorter or longer time depending on the sample starting volume, initial concentration, composition, and desired minimum volume. The reverse spin is 1000g for 2 minutes. Please review the product user guide at the link below:
https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/271/340/pr05485-rev0219.pdfHelpful?
-
-
Hi, how many g's can be used for the ultracell-3K #UFC500396 product?
1 answer-
The recommended speed with a 35 degree fixed angle rotor is 14,000 g with a reverse spin of 1000 g. This information can be found at this link: https://www.sigmaaldrich.com/products/protein-biology/protein-sample-prep/amicon-centrifugals#ultracentrifugal
Helpful?
-