Accéder au contenu
Merck
Toutes les photos(2)

Principaux documents

S2GPU01RE

Millipore

Système de filtration stérile sous vide Stericup-GP Quick Release

pore size 0.22 μm, polyethersulfone membrane, funnel capacity 150 mL, pack of 12 ea

Synonyme(s) :

SCGPU01RE

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme

Sélectionner une taille de conditionnement

12 UNITS
197.00 CHF

197.00 CHF


Date d'expédition estimée le29 mars 2025


Demander des informations complémentaires

Sélectionner une taille de conditionnement

Changer de vue
12 UNITS
197.00 CHF

About This Item

Code UNSPSC :
41104914
eCl@ss :
32031623
Nomenclature NACRES :
NB.24
Dimension de pores:
0.22 μm pore size
Hauteur:
120 mm
Capacité:
150 mL
Diamètre:
12.5 cm
Diam. du filtre:
73 mm
Surface de filtration:
40 cm2
Capacité de l'entonnoir:
150 mL
Conditionnement:
pack of 12 ea
Matériaux:
polyethersulfone membrane
polystyrene bottle
polystyrene funnel(s)
polystyrene housing

197.00 CHF


Date d'expédition estimée le29 mars 2025


Demander des informations complémentaires

Matériaux

polyethersulfone membrane
polystyrene bottle
polystyrene funnel(s)
polystyrene housing

Niveau de qualité

Stérilité

sterile; irradiated

Gamme de produits

Stericup®

Caractéristiques

hydrophilic

Conditionnement

pack of 12 ea

Paramètres

45 °C max. temp.

Description

2.4 mL (hold-up volume)

Technique(s)

sterile filtration: suitable

Hauteur

120 mm

Capacité

150 mL

Diamètre

12.5 cm

Diam. du filtre

73 mm

Surface de filtration

40 cm2

Capacité de l'entonnoir

150 mL

Matrice

Express PLUS

Dimension de pores

0.22 μm pore size

Raccords

inlet funnel
outlet flask (Receiver)

Conditions d'expédition

ambient

Description générale

Cet article est le remplaçant direct de SCGPU01RE
Travaillez facilement et filtrez en toute confiance avec les systèmes de filtration Stericup® et Steritop®.

Les dispositifs de filtration stérilisante Stericup® et Steritop® utilisent des membranes fiables et hautement performantes pour une filtration stérilisante optimale des réactifs, tampons et milieux de laboratoire. Ces dispositifs associent des débits et des volumes filtrés supérieurs à une faible liaison non spécifique et à une conception stable et évitant tout basculement.

Cette unité de filtration à membrane en polyéthersulfone (PES) Stericup® de 0,22 µm de dimension de pores associe un flacon avec ouverture de 150 ml avec un flacon de réception de 150 ml et un bouchon pour le traitement et le stockage.

Application

Les systèmes Stericup® et Steritop® sont conçus pour réduire la formation de mousse et la dénaturation des protéines tout en optimisant le débit. Ils peuvent être utilisés pour la filtration stérilisante sous vide de solutions aqueuses telles que les milieux de culture tissulaire et les fluides biologiques.
  • Milieux de culture cellulaire ± additifs
  • Tampons
  • Solutions biologiques
Produit réservé à la recherche

Caractéristiques et avantages

  • L'entonnoir du filtre Quick Release se déconnecte du flacon de réception en un quart de tour, ce qui réduit le risque de déversement et facilite la manipulation sur la paillasse ou sous la hotte.
  • L'identification en gras du produit sur l'entonnoir Steritop® affiche clairement les caractéristiques de la membrane, notamment la composition et la taille des pores, pour une sélection rapide du produit adapté à l'application.
  • Le bouchon à fermeture par clic est muni d'une collerette et est modifié pour assurer une prise en main sûre aussi bien en conditions humides que sèches et une butée tactile confirme que la fermeture est sécurisée. Ne vous inquiétez pas du risque de déversement ou de contamination du contenu stérilisé.
  • Une large zone d'écriture dépolie sur le flacon de réception et la couleur plus claire du bouchon permettent un étiquetage clair pour améliorer la lisibilité et réduire les bavures.
  • Le bouchon à fermeture par clic repose sur le côté pour éviter tout risque de contamination.
  • Les flacons de réception sont empilables pour gagner de l'espace de stockage.

Informations légales

EXPRESS PLUS is a trademark of Merck KGaA, Darmstadt, Germany
Millipore is a registered trademark of Merck KGaA, Darmstadt, Germany
Stericup is a registered trademark of Merck KGaA, Darmstadt, Germany

Vous ne trouvez pas le bon produit ?  

Essayez notre Outil de sélection de produits.


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Articles

Evaluation of sterile filtration devices for protein preservation in sterile filtration of cell culture media.

Contenu apparenté

This article shows that a PES membrane containing Stericup Quick Release filter provides an alternative for the pluripotent expansion of embryonic stem cells.

Questions

1–10 of 15 Questions  
  1. What tubing can be used with Stericup® and Steritop® vacuum filters?

    1 answer
    1. Stericup® and Steritop® filters are fitted with a 1/4” tube adapter. We recommend 3/16 in. (4.8 mm) ID silicone tubing to fit this tube adapter: https://www.sigmaaldrich.com/product/mm/xx7100004

      Helpful?

  2. What leachables are detected during filtration processes using Stericup® filters?

    1 answer
    1. We have not performed extractables/leachables studies for our Stericup® filters.

      Helpful?

  3. Can Stericup® bottles be placed inside freezers for long-term storage of media?

    1 answer
    1. You can successfully freeze and store many aqueous solutions (such as culture media) in Stericup® bottles at temperatures up to -20 °C (-4 °F). It is strongly recommended that you run a sample stability trial under your actual storage conditions prior to using Stericup® bottles for frozen storage.

      Helpful?

  4. What Bacterial Endotoxins Test is used?

    1 answer
    1. The test method used complies with USP 85 and EP 2.6.14 to ensure the absence of endotoxin in our products.

      Helpful?

  5. What is the chemical compatibility of the various Stericup® and Steritop® filters?

    1 answer
    1. Please refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf

      Helpful?

  6. What is the expiration date of Stericup® and Steritop® filters?

    1 answer
    1. Typically 3 years from sterilization.

      Helpful?

  7. Can we filter oil-type liquids with Stericup® filters?

    1 answer
    1. Likely not, due to pore size/possible fouling/chemical compatibility. Refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf

      Helpful?

  8. The User Guide says “Use only glass or plastic bottles designed for vacuum applications”. Can you specify which bottles are compatible?

    1 answer
    1. Steritop® Quick Release bottle top units require a vacuum-rated receiver bottle with either a GL33 or GL45 mm closure thread as specified. Steritop® E bottle top units require a vacuum-rated receiver bottle with a GL45 mm closure thread. Bottles no larger than 2 L should be used.
      Glass bottles, GL33:
      • Wheaton media bottles (glass), 500 mL (Product Z364886)
      • Wheaton media bottles (glass), 1 L (Product Z364894)
      Glass bottles, GL45
      • Corning® glass media storage bottle, 125 mL (Product CLS1399125)
      • Corning® glass media storage bottle, 250 mL (Product CLS1399250)
      • Corning® glass media storage bottle, 500 mL (Product CLS1399500)
      • Corning® glass media storage bottle, 1 L (Product CLS13991L)
      • Pyrex® round media storage bottle, 500 mL (Product CLS1395500)
      • Pyrex® round media storage bottle, 1 L (Product CLS13951L)
      • KIMBLE® KIMAX® Media bottle, 250 mL (Product DWK14395250)
      • KIMBLE® KIMAX® Media bottle, 500 mL (Product DWK14395500)
      • KIMBLE® KIMAX® Media bottle, 1 L (Product DWK143951000)
      Plastic (pre-sterile) bottles, GL45:
      • Stericup® Quick Release Receiver flask, 250 mL (Product S200B02RE)
      • Stericup® Quick Release Receiver flask, 500 mL (Product S200B05RE)
      • Stericup® Quick Release Receiver flask, 1000 mL (Product S200B10RE)

      Helpful?

  9. Are Stericup® and Steritop® filters GMP-certified?

    1 answer
    1. No, Stericup® and Steritop® devices are not GMP-approved.

      Helpful?

  10. What is the maximum processing volume for Stericup® and Steritop® filters? Can I add more volume after initial filtration?

    1 answer
    1. All Stericup® and Steritop® filters were developed for single-use application. The maximum volume is dependent on the receiver bottle capacity. Stericup® filters come with a receiver bottle with a specified maximum volume. For Steritop® filters, the maximum recommended volume is 2 L with an appropriate-sized receiver bottle. Larger processing volumes can result in membrane fouling, increase chance of spillage and contamination, and lead to possible airlock*.
      *Note that devices with PES membranes can airlock if filtered to dryness. Some liquid must be left on top of the filter, then the system stopped, receiver changed or emptied, and more sample volume added before restart. This increases the chance of spillage.

      Helpful?

1–10 of 15 Questions  

Reviews

No rating value

Active Filters

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique