Accéder au contenu
Merck
Toutes les photos(2)

Principaux documents

719846

Sigma-Aldrich

Resomer® X 206 S, poly(dioxanone)

Synonyme(s) :

PDS

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme

Sélectionner une taille de conditionnement

5 G
279.00 CHF

279.00 CHF


Check Cart for Availability

Devis pour commande en gros

Sélectionner une taille de conditionnement

Changer de vue
5 G
279.00 CHF

About This Item

Formule linéaire :
(C4H6O3)n
Numéro CAS:
Numéro MDL:
Code UNSPSC :
12162002
Nomenclature NACRES :
NA.23

279.00 CHF


Check Cart for Availability

Devis pour commande en gros

Forme

solid

Niveau de qualité

Intervalle de dégradation

<6 months

Viscosité inhérente

1.5-2.2 dL/g, 0.1 % (w/v) in hexafluoroisopropanol(30 °C, Ubbelohde) (size 0c glass capillary viscometer)

Température de transition

Tg −10-−5 °C
Tm 110-115 °C

Température de stockage

−20°C

Chaîne SMILES 

O1CCOC(=O)C1

InChI

1S/C4H6O3/c5-4-3-6-1-2-7-4/h1-3H2

Clé InChI

VPVXHAANQNHFSF-UHFFFAOYSA-N

Description générale

Polydioxanone (PDO) is a colorless, crystalline, highly flexible and resorbable biopolymer.[1]

Application

PDO is widely used as a monofilament wound suture.[2] PDO/elastin-based blends prepared by electrospinning may be used as cardiovascular grafts.[1]

Informations légales

Product of Evonik
RESOMER is a registered trademark of Evonik Rohm GmbH

Code de la classe de stockage

11 - Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Mitchell D Eggers et al.
Journal of vascular and interventional radiology : JVIR, 23(8), 1023-1030 (2012-07-31)
To test absorbable materials as a prelude to development of an absorbable vena cava filter for the prevention of pulmonary embolism (PE). Three absorbing polymer candidates, poliglecaprone (Monocryl; sizes 4-0 and 1), polyglactin (Vicryl; sizes 4-0 and 1), and polydioxanone
O Hakimi et al.
European cells & materials, 24, 344-357 (2012-10-24)
Rotator cuff tendon pathology is thought to account for 30-70 % of all shoulder pain. For cases that have failed conservative treatment, surgical re-attachment of the tendon to the bone with a non-absorbable suture is a common option. However, the failure
Jean W M Gardeniers et al.
Clinical orthopaedics and related research, 471(7), 2225-2230 (2013-03-06)
Surgical treatment options for sternoclavicular joint luxations described in the literature are numerous, although all have limitations. Therefore, there is no favorable surgical treatment for sternoclavicular luxations when nonoperative treatment has failed. We developed the polydioxanone (PDS) envelope plasty, a
Ruan Zheng et al.
European review for medical and pharmacological sciences, 16(7), 942-948 (2012-09-08)
With the development of surgical techniques and biomedical material, increasing synthetic materials are applied to the chest wall reconstruction, such as autologous rib, muscle flap, bovine pericardium and sheet metal. To detect the safety and efficiency of synthetic material Polydioxanone
Georgette Oni et al.
Plastic and reconstructive surgery, 130(4), 535e-540e (2012-09-29)
The use of knotless barbed sutures has shortened operation times for wound closure. In experimental models, their use in tendon surgery is still under investigation. This study looks at the use of barbed sutures in a porcine model for fascial

Articles

Main features of p-dioxanone, glycolide and lactide based copolymers

Interest in utilizing biodegradable polymers for biomedical applications has grown since the 1960s.

AliAliphatic polyesters, including polylactide and polyglycolide, are biodegradable polymers widely used in medical applications.

Immunosuppressive tumor-associated myeloid cells (TAMC) are responsible for glioblastoma (GBM) resistance to immunotherapies and existing standard of care treatments. This mini-review highlights recent progress in implementing nanotechnology in advancing TAMC-targeted therapies for GBM.

Afficher tout

Questions

  1. What's the molecular weight ?

    1 answer
    1. Unfortunately, there is no molecular weight provided by the supplier for this product. The information is proprietary.

      Helpful?

Reviews

No rating value

Active Filters

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique