1.50443
SeQuant™ ZIC®-HILIC 100Å (3.5 µm) HPLC Columns
L × I.D. 250 mm x 2.1 mm HPLC Column, PEEK-lined stainless steel
About This Item
Produits recommandés
product name
SeQuant™ ZIC-HILIC™ 3.5µm,100Å 250 x 2.1 mm, PEEK-lined stainless steel column, suitable for HPLC
Matériaux
PEEK-lined stainless steel column
Niveau de qualité
Agence
suitable for USP L114
Gamme de produits
SeQuant™
Caractéristiques
endcapped: no
Paramètres
550 bar pressure
70 °C max. temp.
Technique(s)
HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
mass spectrometry (MS): suitable (High)
Colonne, L × D.I.
25 cm × 2.1 mm
Matrice
fully porous particle
Groupe de la matrice active
ZIC-HILIC bonding phase
Taille des particules
3.5 μm
Dimension de pores
100 Å pore size
pH de fonctionnement
2-7.5
Technique de séparation
hydrophilic interaction (HILIC)
Température de stockage
no temp limit
Description générale
The silica-based ZIC®-HILIC sorbent has a bonded stationary phase consisting of a highly polar, permanent zwitterion. Separation selectivity is favored by the 1:1 zwitterion charge balance, which makes the ZIC®-HILIC Column overall neutral, with weak, but important, ionic interactions. Tuning of the selectivity on the ZIC®-HILIC Column during method development is facilitated by the pH-inpendent permanent zwitterion, ensuring that only the analytes (and not the column) are affected during eluent optimization.
The Pore size of 100 Å makes this column perfectly suitable for the separation of small polar molecules under HILIC conditions.
The column dimension of 250 mm length x 2.1 mm ID is the optimal choice for the separation of complex samples using a UHPLC or optimized HPLC Instrument providing low dwell volumes.
Thanks to their favorable retention and robust performance, SeQuant™ HILIC columns have become extremely popular in numerous laboratories around the world. For example, US FDA (United States Food and Drug Administration) has recommended SeQuant™ ZIC®-HILIC for analysis of melamine and related substances.
SeQuant™ HILIC columns excel in stability and low bleed. These features make them particularly suitable for LC-MS applications where high background can lead to signal suppression and interference with quantitative measurements while also increasing instrument wear. Their high stability makes these high-performance HILIC columns also attractive for traditional HPLC applications.
Learn more about the Supelco HPLC Column portfolio and Method development:
Brochure: HPLC and UHPLC Column Selection Guide
Brochure: A Practical Guide to HPLC - Method Development Guide
Remarque sur l'analyse
Symmetry (Cytosine): 0.95 - 1.40
Informations légales
Produit(s) apparenté(s)
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique