Accéder au contenu
MilliporeSigma

ASTM D3612-96: GC Analysis of Transformer Gas on Carboxen®-1010 PLOT

ASTM D3612-96: GC Analysis of Transformer Gas on Carboxen®-1010 PLOT suitable for GC

Matériaux

Colonne analytique

Réf. du produit
Description
Tarif

PLOT - Carboxen-1010

L × I.D. 30 m × 0.53 mm, average thickness 30 μm

CONDITIONS

column

Carboxen-1010 PLOT, 30 m x 0.53 mm I.D. (25467)

oven

35 °C (8.5 min), 24 °C/min to 250 °C

inj. temp.

200 °C

detector

TCD, 230 °C, Methanizer, 375 °C, and FID, 230 °C in series

carrier gas

argon, 3.0 mL/min

injection

10.0 μL direct using a sample valve, 150 °C

sample

9 analytes, each at 500 ppm

Description