GE17-0507-01
Mono S® HR 16/10
About This Item
Produits recommandés
ligand
-OCH2CH(OH)CH2OCH2CH(OH)CH2SO3-
Matériaux
PEEK column
Description
Ion Exchanger Type (Methyl sulfonate strong cation)
Conditionnement
pkg of 1 ea
Paramètres
435 psi
Taille du lit
16 mm × 100 mm
Volume du lit
20 mL
D.I. de la colonne
16 mm
Taille
Matrice
polymeric
Groupe de la matrice active
methyl sulfonate phase
Taille moy. des particules
10 μm
cleaning
1-14
Plage de travail
2-12
Technique de séparation
cation exchange
Description générale
Application
- Monodisperse 10 μm porous beads yield high resolution, dynamic capacity, reproducibility, and durability.
- Maximum resolution is achieved from the efficiency of small, perfectly spherical monodispersed particles optimally packed in columns coupled with the excellent selectivities of the Q ion exchangers.
- Compatible with ÄKTA® design, FPLC™ System, and other high-performance LC systems.
- MonoBeads are also available as Mono P® for chromatofocusing
Stockage et stabilité
Remarque sur l'analyse
Autres remarques
Informations légales
Mention d'avertissement
Warning
Mentions de danger
Conseils de prudence
Code de la classe de stockage
3 - Flammable liquids
Faites votre choix parmi les versions les plus récentes :
Certificats d'analyse (COA)
It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.
Si vous avez besoin d'assistance, veuillez contacter Service Clients
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Articles
This page shows volatile and non-volatile buffer suggestions for anion and cation exchange chromatography.
This page covers the standard ÄKTAdesign configurations for simple IEX chromatography.
This page covers practical problems that may lead to a non-ideal IEX separation and their solutions.
This page covers detailed aspects of each step in an IEX separation to improve resolution and overall performance.
Protocoles
This page covers using Monobeads for purification of proteins, peptides, or oligonucleotides.
This page shows how to perform column packing and preparation for ion exchange chromatography and chromatafocusing when using Tricorn or XK columns available from Cytiva.
This page clarifies sample preparation, buffer exchange and desalting, removal of lipoproteins, phenol red, and low molecular weight contaminants in Ion exchange chromatography.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique