Accéder au contenu
MilliporeSigma
Toutes les photos(1)

Documents

ECM210

Sigma-Aldrich

QCM Endothelial Cell Invasion Assay (24 well, colorimetric)

This QCM Endothelial Cell Invasion Assay provides an in vitro model to quickly screen factors that can regulate endothelial invasion. The assay is performed in an invasion chamber using a basement membrane protein coated on the porous insert.

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12352207
eCl@ss :
32161000
Nomenclature NACRES :
NA.84

Niveau de qualité

Fabricant/nom de marque

Chemicon®
QCM

Technique(s)

cell based assay: suitable

Méthode de détection

colorimetric

Conditions d'expédition

wet ice

Description générale

Also available: Cell Comb Scratch Assay! Get biochemical data from a scratch assay!Click Here

Introduction
Endothelial cells (EC) invade through the basement membrane (BM) to form sprouting vessels. The invasion process consists of the secretion of matrix metalloproteases (MMP) to degrade basement membrane, the activation of endothelial cells, and the migration of EC across the basement membrane. The understanding of EC invasion is important for studying the mechanism of angiogenesis in injured tissue as well as in disease such as cancer.

Cell migration may be evaluated through several different methods, the most widely accepted of which is the Boyden Chamber assay. The Boyden Chamber system uses two-chamber system which a porous membrane provides an interface between two chambers. Cells are seeded in the upper chamber and chemoattractants placed in the lower chamber. Cells in the upper chamber migrate toward the chemoattractants by passing through the porous membrane to the lower chamber. Migratory cells are then stained and quantified.

Application

Millipore’s QCM Endothelial Cell Invasion Assay provides an in vitro model to quickly screen factors that can regulate endothelial invasion. The assay is performed in an invasion chamber using a basement membrane protein coated on the porous insert. The level of coating and the pore size is optimized for endothelial cells so the researcher may utilize this kit to mimic physiological condition. After cell invasion has occurred, the researcher can select a staining method to quantify the number of cells that have invaded through the chamber. Millipore offers a colorimetric staining kit (ECM210) and a fluorometric kit staining reagent (ECM211) for both convenience and efficiency.
Research Category
Apoptosis & Cancer

Cell Structure

Conditionnement

Sufficient for 24 assays

Composants

1. Cell Invasion Plate Assembly: (Part No. CS203020) Two 24-well plates each containing 12 ECMatrix-coated 3 m inserts per plate.

2. Cell Stain Solution: (Part No. 90144)* One bottle.

3. Extraction Buffer: (Part No. 90145) One bottle.

4. 24-well Stain Extraction Plate: (Part No. 2005871) One each.

4. 24-well Stain Extraction Plate: (Part No. 2005871) One each.

5. 96-well Stain Quantitation Plate: (Part No. 2005870) One each.

6. Cotton Swabs: (Part No. 10202) Fifty each.

7. Forceps: (Part No. 10203) One each.

Stockage et stabilité

Store kit materials at 2° to 8°C for up to their expiration date. Do not freeze.

Informations légales

Accutase is a registered trademark of Innovative Cell Technologies, Inc.
CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany

Clause de non-responsabilité

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Pictogrammes

FlameExclamation mark

Mention d'avertissement

Danger

Mentions de danger

Classification des risques

Eye Irrit. 2 - Flam. Liq. 2

Code de la classe de stockage

3 - Flammable liquids

Point d'éclair (°F)

53.6 °F

Point d'éclair (°C)

12 °C


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Yingying Yu et al.
Bioengineered, 12(1), 4681-4696 (2021-08-05)
Accumulating evidence indicates that INHBA (Inhibin β-A, a member of the TGF-β superfamily) functions as an oncogene in cancer progression. However, little is known as to how INHBA regulates the progression and aggressiveness of breast cancer (BC). This study explored
Sylvain Tollis et al.
ACS chemical biology, 17(3), 680-700 (2022-02-25)
Background: Lower survival rates for many cancer types correlate with changes in nuclear size/scaling in a tumor-type/tissue-specific manner. Hypothesizing that such changes might confer an advantage to tumor cells, we aimed at the identification of commercially available compounds to guide

Articles

Cell based angiogenesis assays to analyze new blood vessel formation for applications of cancer research, tissue regeneration and vascular biology.

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique