1.50142

Supelco

Purospher® RP-18 (5 µm) HPLC Columns

L × I.D. 125 mm x 4 mm LiChroCART® HPLC cartridge, manuCART holder required for use

Synonyme(s) :

Purospher® RP-18 (5 µm) LiChroCART® 125-4

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41115709
Nomenclature NACRES :
SB.52

product name

Purospher® RP-18 (5 µm), L × I.D. 125 mm x 4 mm LiChroCART® HPLC cartridge, manuCART holder required for use

Matériaux

stainless steel column

Niveau de qualité

Agence

suitable for USP L1

Gamme de produits

Purospher®

Caractéristiques

endcapped: no

Conditionnement

1 ea of

Ampleur du marquage

18.5% Carbon loading

Paramètres

250 bar pressure
65 °C max. temp.

Technique(s)

HPLC: suitable
LC/MS: suitable
mass spectrometry (MS): suitable (Medium)

Colonne, L × D.I.

12.5 cm × 4 mm

Matrice

fully porous particle

Groupe de la matrice active

C18 bonding phase

Taille des particules

5 μm

Dimension de pores

90 Å pore size

pH de fonctionnement

2-7.5

Technique de séparation

reversed phase

Température de stockage

no temp limit

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

HPLC cartridge
Purospher® RP-18 is designed for the separation of problematic basic compounds with simple neutral eluents. In addition Purospher<TMSYMBOL></TMSYMBOL> RP-18 allows the separation of hydrophilic compounds with aqueous mobile phase. Purospher<TMSYMBOL></TMSYMBOL> RP-18 is based upon a high-purity, metal free silica. The multi-step chemical modification and deactivation of the surface enables a peak-tailing free elution of basic and chelating compounds. Purospher<TMSYMBOL></TMSYMBOL> RP-18 is not suitable for the separation of acidic compounds. The good chemical stability of Purospher<TMSYMBOL></TMSYMBOL> RP-18 enables the use of mobile phase conditions at pH 8 for a long period of time. The connection to the HPLC system is being accomplished by use of the manu-CART NT cartrige holder (1.51486).

Remarque sur l'analyse

Pressure: ≤ 70 bar
Theoretical Plates (N/m) (Toluene): ≥ 70000
Symmetry (Toluene): 0.8 - 1.4
Capacity factor (Toluene): ≥ 1.0

Informations légales

LICHROCART is a registered trademark of Merck KGaA, Darmstadt, Germany
MANUCART is a trademark of Merck KGaA, Darmstadt, Germany
Purospher is a registered trademark of Merck KGaA, Darmstadt, Germany

Code de la classe de stockage

11 - Combustible Solids


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique