Accéder au contenu
MilliporeSigma
Toutes les photos(1)

Principaux documents

739553

Sigma-Aldrich

Poly(styrene-block-methyl methacrylate)

average Mn 32,000, block ratio of 2:1

Synonyme(s) :

PS-PMMA, block copolymer, Poly(b-methyl methacrylate-polystyrene), PS-block-PMMA, PS-PMMA

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Numéro CAS:
Code UNSPSC :
12162002

Forme

solid

Poids mol.

average Mn 10,000 (PMMA)
average Mn 22,000 (polystyrene)
average Mn 32,000

Température de transition

Tm 351-356 °C

Mw/Mn

<1.2

InChI

1S/C8H8.C5H8O2/c1-2-8-6-4-3-5-7-8;1-4(2)5(6)7-3/h2-7H,1H2;1H2,2-3H3

Clé InChI

ADFPJHOAARPYLP-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

22 kDa PS; 10 kDa PMMA; m ~200; n ~100

Pictogrammes

Exclamation mark

Mention d'avertissement

Warning

Mentions de danger

Conseils de prudence

Classification des risques

Eye Irrit. 2

Code de la classe de stockage

13 - Non Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Novel fabrication of 2D and 3D inverted opals and their application.
Jae Ah Lee et al.
Small (Weinheim an der Bergstrasse, Germany), 7(18), 2581-2586 (2011-08-03)
F N K Kwong et al.
The Journal of bone and joint surgery. British volume, 88(1), 120-122 (2005-12-21)
The outcome of a cemented hip arthroplasty is partly dependent on the type of cement which is used. The production of an interface gap between the stem and the cement mantle as a result of shrinkage of the cement, may
M H Geiger et al.
Clinical orthopaedics and related research, (382)(382), 258-266 (2001-01-12)
This controlled study compared the strength and porosity of 48 polymethylmethacrylate cement-implant constructs prepared with open bowl versus vacuum mix technique. Forty-eight blast finished stainless steel rods of 13 mm diameter were implanted with centralizers into 17-mm inner diameter tubes
S J Breusch et al.
Acta orthopaedica Scandinavica, 72(1), 29-35 (2001-05-01)
In a cadaver study, we prepared 29 paired human cadaver femora using 3 different broaches of identical geometry but different surface characteristics. In one group of 20 pairs, preparation with chipped-toothed broaches was compared to diamond-shaped broaches; in the other
MN: Surgical LPN files product liability suit: cement Mfgr.'s failure to warn of health hazard.
Nursing law's Regan report, 42(8), 3-3 (2004-08-11)

Questions

Reviews

No rating value

Active Filters

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique