Accéder au contenu
MilliporeSigma
Toutes les photos(2)

Documents

202746

Sigma-Aldrich

Barium fluoride

99.99% trace metals basis

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule empirique (notation de Hill):
BaF2
Numéro CAS:
Poids moléculaire :
175.32
Numéro CE :
Numéro MDL:
Code UNSPSC :
12352302
ID de substance PubChem :
Nomenclature NACRES :
NA.23

Pureté

99.99% trace metals basis

Forme

solid

Impuretés

≤150.0 ppm Trace Metal Analysis

Point d'ébullition

2260 °C (lit.)

Densité

4.89 g/mL at 25 °C (lit.)

Chaîne SMILES 

F[Ba]F

InChI

1S/Ba.2FH/h;2*1H/q+2;;/p-2

Clé InChI

OYLGJCQECKOTOL-UHFFFAOYSA-L

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Caractéristiques et avantages

Primary glass modifier in fluorozirconate glasses.

Pictogrammes

Exclamation mark

Mention d'avertissement

Warning

Mentions de danger

Classification des risques

Acute Tox. 4 Inhalation - Acute Tox. 4 Oral

Code de la classe de stockage

13 - Non Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 1

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Les clients ont également consulté

Jian Ruan et al.
Optics express, 17(7), 5163-5169 (2009-04-01)
Bi-doped BaF(2) crystal was grown by the temperature gradient technique and its spectral properties were investigated. The absorption, emission and excitation spectra were measured at room temperature. Two broadband emissions centered at 1070 and 1500 nm were observed in Bi-doped
S Tavernier et al.
Medical progress through technology, 17(3-4), 237-241 (1991-01-01)
The work presented is part of a design study for a Positron Emission Tomograph (PET) scanner based on the use of BaF2 scintillator and photosensitive wire chambers. The detection efficiency for gamma radiation of 511 keV is found close to
J Zou et al.
The Journal of biological chemistry, 272(9), 6073-6077 (1997-02-28)
The role of the cytoplasmic regions of interleukin-12 receptors (IL-12R) beta1 and beta2 in stimulating proliferation was examined. The transmembrane and cytoplasmic regions of IL-12Rbeta1 or IL-12Rbeta2 were fused to the extracellular domain of the epidermal growth factor (EGF) receptor
W H Wong
Journal of nuclear medicine : official publication, Society of Nuclear Medicine, 29(3), 338-347 (1988-03-01)
Bismuth germanate (BGO) and barium fluoride (BaF2) scintillators are presently used in positron emission tomegraphy (PET) cameras. This study evaluates the important PET performance parameters of image resolution, true sensitivity, scatter background, accidental background, and realistic maximum radioactivity in the
C W van Eijk et al.
Medical progress through technology, 17(3-4), 243-247 (1991-01-01)
A detector has been developed for position sensitive registration of annihilation radiation. The 511 keV gamma rays are detected in a set of BaF2 scintillation crystals coupled to low pressure TMAE-filled photosensitive multi wire chambers. In a first experimental detector

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique