Accéder au contenu
Merck

Formation of volatile halogenated by-products during chlorination of isoproturon aqueous solutions.

Chemosphere (2001-10-11)
A Lopez, G Mascolo, R Ciannarella, G Tiravanti
RÉSUMÉ

The present paper deals with the formation of volatile halogenated by-products (POX) during the chlorination (160 mg/l) of aqueous solutions of the herbicide isoproturon (40 mg/l). Chlorination reactions have been carried out over 48 h, at ambient temperature, at two pHs (6 and 9) and in the presence or not of bromide ions (80 mg/l). The main results obtained have been as follows: (1) in the presence of bromide, isoproturon degradation is rather fast and it results affected by pH, complete isoproturon degradation is achieved within 1 and 15 min at pH 6 and 9, respectively; (2) in the absence of bromide herbicide degradation is slow (complete degradation is achieved within 180 min) and it is not affected by pH; (3) at pH 6, regardless of the presence of bromide, the maximum amount of POX formed is low (approximately 15 micromol X-/l) and remains constant during the reaction; (4) at pH 9 the amount of POX formed is far greater and continuously increases during the reaction, reaching a value of about 110 micromol X-/l after 48 h; (5) two different groups of by-products have been identified by solid phase micro extraction (SPME)-gas chromatography (GC)-mass spectrometry (MS) for the reactions carried out with or without bromide; among them, aliphatic as well as aromatic by-products containing chlorine, bromine or both halogens are present even though the most abundant are halogenated-methane derivatives (haloforms); pH value affects the amount of these by-products but does not modify their chemical nature.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Fibres SPME polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
Fibres SPME polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
SPME StableFlex fiber assortment kit, for use with manual holder
Supelco
SPME StableFlex fiber assortment kit, needle size 23 ga, for use with autosampler
Supelco
SPME fiber assembly, Carbowax-Polyethylene Glycol (PEG) Coating, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), fused silica fiber, df 65 μm(PDMS/DVB, for use with manual holder, needle size 23 ga
Supelco
Fibres SPME polyacrylate (PA), df 85 μm(PA, for use with manual holder, needle size 24 ga
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), for use with autosampler, needle size 23 ga, metal alloy fiber, fiber L 2 cm