Accéder au contenu
Merck

Design and testing of a new sampler for simplified vacuum-assisted headspace solid-phase microextraction.

Analytica chimica acta (2016-05-31)
Evangelia Yiantzi, Nicolas Kalogerakis, Elefteria Psillakis
RÉSUMÉ

The design and testing of a new and low-cost experimental setup used for vacuum-assisted headspace solid-phase microextraction (Vac-HSSPME) is reported here. The device consists of a specially designed O-ring seal screw cap offering gas-tight seal to commercially available headspace vials. The new polytetrafluoroethylene (PTFE) cap was molded by a local manufacturer and had a hole that could tightly accommodate a septum. All operations were performed through the septum: air evacuation of the sampler, sample introduction and HSSPME sampling. The analytical performance of the new sampler was evaluated using 22 mL headspace vials with 9 mL water samples spiked with polychlorinated biphenyls (PCBs). Several experimental parameters were controlled and the optimized conditions were: 1000 rpm agitation speed; 30 min extraction time; 40 °C sampling temperature; polydimethylsiloxane-divinylbenzene (PDMS-DVB) fiber. The lack of accurate Henry's law constant (KH) values and information regarding how they change with temperature was a major limitation in predicting the phase location of evaporation resistance during Vac-HSSPME. Nevertheless, the combined effects of system conditions indicated the increasing importance of gas phase resistance with increasing degree of PCBs chlorination. Stirring enhancements were not recorded for the higher chlorinated PCBs suggesting that the hyperhydrophobic gas/water interface was the preferred location for these compounds. Analytically, the developed method was found to yield linear calibration curves with limits of detection in the sub ng L(-1) level and relative standard deviations ranging between 5.8 and 14%. To compensate for the low recoveries of the higher chlorinated PCB congeners in spiked river water the standard addition methodology was applied. Overall, the compact design of the new and reusable sample container allows efficient HSSPME sampling of organic analytes in water within short extraction times and at low sampling temperatures compared to other published HSSPME methods.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
Fibres SPME polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
Fibres SPME polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
SPME fiber assembly, Carbowax-Polyethylene Glycol (PEG) Coating, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Supelco
SPME StableFlex fiber assortment kit, for use with manual holder
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
SPME StableFlex fiber assortment kit, needle size 23 ga, for use with autosampler
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), fused silica fiber, df 65 μm(PDMS/DVB, for use with manual holder, needle size 23 ga
Supelco
Fibres SPME polyacrylate (PA), df 85 μm(PA, for use with manual holder, needle size 24 ga
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), for use with autosampler, needle size 23 ga, metal alloy fiber, fiber L 2 cm