Unfortunately, the matrix effect with other biogenic amines is not investigated for this kit.
MAK432
Histamine Quantification Assay Kit
sufficient for 100 colorimetric tests
Synonyme(s) :
Histamine Detection Kit
Sélectionner une taille de conditionnement
386,00 €
Sélectionner une taille de conditionnement
About This Item
386,00 €
Produits recommandés
Utilisation
sufficient for 100 colorimetric tests
Niveau de qualité
Application(s)
food and beverages
Méthode de détection
colorimetric
Température de stockage
−20°C
Catégories apparentées
Description générale
Application
- Food and Beverage Testing
- Bacterial Fermentation Analysis
Caractéristiques et avantages
- Supportive calculator (Click here to download a calculator excel file) Analyze results based on your experimental data!
- Quick instruction bench card - to assure your experimental success
- More experiments in one kit - contains sufficient reagents for 100 tests
Adéquation
Principe
Autres remarques
Code de la classe de stockage
12 - Non Combustible Liquids
Faites votre choix parmi les versions les plus récentes :
Certificats d'analyse (COA)
Vous ne trouvez pas la bonne version ?
Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
-
Will this kit give matric effect with other biogenic amines like Putrescine, cadaverine?
1 answer-
Helpful?
-
-
How long is the assay buffer in the MAK432-1KT Histamine Quantification Assay Kit stable for when stored at 2-8 degrees? The technical bulletin indicates that all components are good for 2 years at -20 degrees, but please confirm the stability period for the assay buffer once it's been thawed and stored at 4 degrees.
1 answer-
The Assay Buffer remains stable at 2-8 degrees Celsius at least until the expiration date of the kit.
Helpful?
-
-
What is the recommend type plate for use with the MAK432-1KT Histamine Quantification Assay Kit? is it ok to use a Nunc Maxisorp plate.
1 answer-
QC testing for the kit recommends the use of M2936-100EA Greiner 96 well plates, polystyrene.
Helpful?
-