Accéder au contenu
Merck
Toutes les photos(2)

Documents

KCQS08

Sigma-Aldrich

KiCqStart® One-Step Probe RT-qPCR ReadyMix, Low ROX

with Low ROX for ABI and Stratagene instruments

Synonyme(s) :

KiCqStart® One Step Probe RT-qPCR Readymix

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41106300
Nomenclature NACRES :
NA.55

Forme

liquid

Utilisation

sufficient for 500 reactions

Caractéristiques

dNTPs included
hotstart

Conditions de stockage

protect from light

Technique(s)

qPCR: suitable

Couleur

light blue

Entrée

purified RNA

Compatibilité

ABI 7500 Fast
ABI 7500
ABI QuantStudio
ABI ViiA 7
Agilent AriaMx
Douglas Scientific IntelliQube
Qiagen Corbett Rotor-Gene Q
Strategene Mx3000P
Strategene Mx3005P
Strategene Mx4000

Méthode de détection

probe-based

Conditions d'expédition

dry ice

Température de stockage

−20°C

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Catégories apparentées

Description générale

KiCqStart® One-Step Probe RT-qPCR ReadyMix is a ready-to-use, highly sensitive master mix for reverse transcription quantitative PCR (RT-qPCR) of RNA templates using hybridization probe detection chemistries such as TaqMan® 5′-hydrolysis probes on real-time PCR systems (refer to instrument compatibility section to select the appropriate reagent for your machine). First-strand cDNA synthesis and PCR amplification are carried out in the same tube without opening between procedures. It is ideal for highly sensitive quantification of RNA viruses or low abundance RNA targets as well as high throughput gene-expression studies. The system has been optimized to deliver maximum RT-PCR efficiency, sensitivity, and specificity in reduced reaction volumes and fast cycle times.

KiCqStart® One-Step Probe RT-qPCR ReadyMix contains all required components for RT-qPCR except RNA template and probe. It is compatible with all dual-labeled probe chemistries. The reverse transcriptase is an engineered M-MLV with reduced RNase H activity and improved activity and stability at higher temperatures. The use of higher temperatures (50 to 55°C) for the first-strand step of one-step RT-qPCR provides higher specificity for primer annealing and disruption of RNA secondary structure that can interfere with cDNA synthesis.

KiCqStart® One-Step Probe RT-qPCR ReadyMix is highly resistant to PCR inhibitors. A key component of the ReadyMix is an ultra-pure, highly processive, thermostable DNA polymerase that is combined with high avidity monoclonal antibodies. This provides an extremely stringent automatic hot-start that minimizes the potential for primer-dimer and other non-specific PCR artifacts. The light blue color of the inert dye simplifies reaction assembly in white, or clear, plates and helps to minimize pipetting or mixing errors. The dye does not interfere with qPCR performance or affect the stability of the product.

Application

Different real-time PCR systems employ different strategies for normalization of fluorescent signals and correction of well-to-well optical variations. It is critical to match the appropriate qPCR reagent to your specific instrument.KiCqStart® One-Step Probe RT-qPCR ReadyMix does not contain an internal reference dye. Compatible instruments include:
  • Applied Biosystems® 7500
  • Applied Biosystems 7500 Fast
  • Applied Biosystems ViiA 7
  • Applied Biosystems QuantStudio
  • Agilent® AriaMx
  • Douglas Scientific IntelliQube
  • QIAGEN® Rotor-Gene® Q
  • Stratagene Mx3000P®
  • Stratagene Mx3005P®
  • Stratagene Mx4000

Caractéristiques et avantages

  • Assay results in as little as 33 minutes
  • Highly efficient and sensitive real-time PCR results
  • Little/no optimization required

Composants

2X reaction buffer containing dATP, dCTP, dGTP, dTTP, magnesium chloride, reverse transcriptase, RNase inhibitor protein, hot-start DNA polymerase, ROX reference dye, inert blue qPCR dye, and stabilizers

packaging:
500 reactions* = 5 X 1 mL tubes
*number of reactions based on a 20uL volume

Informations légales

Agilent is a registered trademark of Agilent Technologies, Inc.
Applied Biosystems is a registered trademark of Applera Corporation or its subsidiaries in the US and/or certain other countries
KiCqStart is a registered trademark of QIAGEN Beverly Inc.
Mx3000P is a registered trademark of Agilent Technologies, Inc.
Mx3005P is a registered trademark of Agilent Technologies, Inc.
Mx4000 is a trademark of Agilent Technologies, Inc.
Qiagen is a registered trademark of Qiagen Group
ROX is a trademark of Applera Corporation or its subsidiaries in the US and/or certain other countries
ReadyMix is a trademark of Sigma-Aldrich Co. LLC
Rotor-Gene is a registered trademark of Qiagen GmbH
TaqMan is a registered trademark of Roche Molecular Systems, Inc.

Code de la classe de stockage

10 - Combustible liquids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

R Grace Walton et al.
Physiological reports, 3(6), doi:10-doi:10 (2015-06-04)
Reduced vessel density in adipose tissue and skeletal muscle is associated with obesity and may result in decreased perfusion, decreased oxygen consumption, and insulin resistance. In the presence of VEGFA, Angiopoietin-2 (Angpt2) and Angiopoietin-1 (Angpt1) are central determinants of angiogenesis
Tyler J Kirby et al.
Physiological genomics, 48(2), 145-153 (2015-12-17)
Adipose tissue has profound effects on whole-body insulin sensitivity. However, the underlying biological processes are quite complex and likely multifactorial. For instance, the adipose transcriptome is posttranscriptionally modulated by microRNAs, but the relationship between microRNAs and insulin sensitivity in humans
Tyler J Kirby et al.
Molecular biology of the cell, 27(5), 788-798 (2016-01-15)
Myofibers increase size and DNA content in response to a hypertrophic stimulus, thus providing a physiological model with which to study how these factors affect global transcription. Using 5-ethynyl uridine (EU) to metabolically label nascent RNA, we measured a sevenfold

Articles

RT-qPCR products combine the effective of Reverse Transcriptase with hot-start taq-directed antibody in convenient ReadyMixes for probe-based or SYBR® Green based applications.

PCR assay guide navigates you through primer validation and other assay optimization factors to ensure high sensitivity and specificity for optimum DNA/ RNA quantification.

Challenges in gene expression analysis include mRNA stability, temporal transcription patterns, and mRNA-protein correlation, impacting accuracy.

La réaction en chaîne par polymérase (PCR) est l'une des techniques les plus couramment utilisées en biologie moléculaire. Le procédé de PCR implique trois étapes principales : la dénaturation, l'hybridation des amorces et l'élongation

Afficher tout

Protocoles

KiCqStart One-Step Probe RT-qPCR ReadyMix streamlines RNA template RT-qPCR with high sensitivity.

Contenu apparenté

RT-qPCR detects specific targets with applications in gene expression and pathogen detection.

La RT-qPCR, ou PCR quantitative après transcription inverse, combine les effets de la transcription inverse et de la PCR quantitative, ou PCR en temps réel, pour amplifier et détecter des cibles spécifiques. La RT-qPCR trouve de multiples applications, notamment dans la quantification du niveau d'expression génique, la validation de l'interférence par ARN ou la détection d'agents pathogènes comme les virus.

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique