EMS0011
Low-Artifact Digestion Buffer
Minimizes artifactual deamidation and oxidation during trypsin digestion prior to peptide mapping
Synonyme(s) :
Hi-Fidelity Peptide Mapping Buffer
Sélectionner une taille de conditionnement
193,00 €
Sélectionner une taille de conditionnement
About This Item
193,00 €
Produits recommandés
Forme
liquid
Adéquation
suitable for (peptide mapping)
Conditions d'expédition
wet ice
Température de stockage
2-8°C
Catégories apparentées
Description générale
Endogenous deamidation and oxidation of protein amino acids can be implicated in and be indicative of many diseases, protein turnover, development, and aging. The introduction of these modifications can often affect biological activity, half-life, and immunogenicity.
Current protein digestion workflows often introduce a significant amount of artifactual deamidation and oxidation which prohibits the measurement of the endogenous levels.
The Low Artifact Digestion Buffer allows protein digestion in less than 6 hours with minimized artifactual modifications such as deamidation and oxidation. The amount of oxidation and deamidation introduced during further downstream processing of biotherapeutic antibodies and proteins can be accurately determined. The most commonly deamidated amino acid is Asn especially when followed by small amino acids such as Gly. The most commonly oxidized amino acids are Met, Cys, and to some extent Trp and His.
Code de la classe de stockage
12 - Non Combustible Liquids
Classe de danger pour l'eau (WGK)
nwg
Point d'éclair (°F)
Not applicable
Point d'éclair (°C)
Not applicable
Faites votre choix parmi les versions les plus récentes :
Certificats d'analyse (COA)
Vous ne trouvez pas la bonne version ?
Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Articles
An optimized peptide mapping protocol using NISTmAb as a model monoclonal antibody, shorter incubation times, and improved digestion buffer to demonstrate minimal artificial asparagine deamidation and methionine oxidation.
This application note compares three different column chemistries from the BIOshell™ line of columns with superficially porous particles to evaluate their performance in peptide mapping.
Workflows for monoclonal antibody adalimumab characterization ensure drug safety and efficacy through critical quality attribute analysis.
Method development for protein fingerprinting of AAV serotype 5 using both intact mass analysis and peptide mapping, to determine critical quality attributes for gene therapy, utilizing three different columns.
Protocoles
An optimized LC-MS/MS based workflow for low artifact tryptic digestion and peptide mapping of monoclonal antibody, adalimumab (Humira) using filter assisted sample preparation (FASP).
A step-by-step protocol for released N-linked glycan analysis of the monoclonal antibody adalimumab, based on UHPLC-FLR-MS and procainamide labeling.
Active Filters
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique