o-xylène
Reagent
Synonyme(s) :
1,2-diméthylbenzène
About This Item
Produits recommandés
Densité de vapeur
3.7 (vs air)
Niveau de qualité
Pression de vapeur
<0.1 atm ( 21.1 °C)
16 mmHg ( 37.7 °C)
7 mmHg ( 20 °C)
Pureté
≥98% (GC)
Forme
liquid
Température d'inflammation spontanée
867 °F
Limite d'explosivité
7 %
Couleur
APHA: ≤10
Indice de réfraction
n20/D 1.505 (lit.)
Point d'ébullition
143-145 °C (lit.)
Pf
-26--23 °C (lit.)
Température de transition
flash point 30 °C
Solubilité
0.18 g/L
Densité
0.879 g/mL at 20 °C (lit.)
0.88 g/cm3 at 20 °C
Conditions d'expédition
ambient
Température de stockage
room temp
Chaîne SMILES
Cc1ccccc1C
InChI
1S/C8H10/c1-7-5-3-4-6-8(7)2/h3-6H,1-2H3
Clé InChI
CTQNGGLPUBDAKN-UHFFFAOYSA-N
Vous recherchez des produits similaires ? Visite Guide de comparaison des produits
Application
- Environmental sampling of volatile organic compounds during the 2018 Camp Fire in Northern California.: This study analyzed volatile organic compounds, including o-Xylene, sampled during the 2018 Camp Fire in Northern California, highlighting the analytical methods used to assess environmental exposure and chemical composition in wildfire scenarios (Simms et al., 2021).
- Urinary BTEX, MTBE and naphthalene as biomarkers to gain environmental exposure profiles of the general population.: Focuses on the use of urinary biomarkers, such as BTEX (including o-Xylene), for assessing environmental exposure in populations, demonstrating the integration of analytical chemistry techniques in epidemiological studies (Fustinoni et al., 2010).
- Genotoxic effects of volatile organic compounds in a chemical factory as evaluated by the Tradescantia micronucleus assay and by chemical analysis.: Investigates the genotoxic effects of VOCs, including o-Xylene, in a chemical plant environment, using both biological assays and chemical analysis to evaluate risk and exposure (Kim et al., 2003).
- Time-gated pulsed glow discharge: real-time chemical speciation at the elemental, structural, and molecular level for gas chromatography time-of-flight mass spectrometry.: This paper presents a novel analytical technique for real-time chemical speciation, useful in analyzing compounds like o-Xylene, providing insights into complex analytical methodologies in chemistry (Lewis et al., 2003).
Remarque sur l'analyse
Color (APHA): 10 max
Form: Clear liquid
Infrared Spectrum: Conforms to standard
Mention d'avertissement
Danger
Mentions de danger
Conseils de prudence
Classification des risques
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Aquatic Chronic 3 - Asp. Tox. 1 - Eye Irrit. 2 - Flam. Liq. 3 - Skin Irrit. 2 - STOT SE 3
Organes cibles
Respiratory system
Code de la classe de stockage
3 - Flammable liquids
Classe de danger pour l'eau (WGK)
WGK 2
Point d'éclair (°F)
89.6 °F - closed cup
Point d'éclair (°C)
32.0 °C - closed cup
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique