All Stericup® and Steritop® filters were developed for single use, disposable processing.
S2GPU10RE
Système de filtration stérile sous vide Stericup-GP Quick Release
pore size 0.22 μm, polyethersulfone membrane, funnel capacity 500 mL, pack of 12 ea
Synonyme(s) :
SCGPU10RE
Sélectionner une taille de conditionnement
Sélectionner une taille de conditionnement
About This Item
Produits recommandés
Matériaux
polyethersulfone membrane
polystyrene bottle
polystyrene funnel(s)
polystyrene housing
Niveau de qualité
Stérilité
sterile; irradiated
Gamme de produits
Stericup®
Caractéristiques
hydrophilic
Conditionnement
pack of 12 ea
Paramètres
45 °C max. temp.
Description
2.4 mL (hold-up volume)
Technique(s)
sterile filtration: suitable
Hauteur
299 mm
Capacité
1000 mL
Diamètre
12.5 cm
Diam. du filtre
73 mm
Surface de filtration
40 cm2
Capacité de l'entonnoir
500 mL
Matrice
Express PLUS™
Dimension de pores
0.22 μm pore size
Raccords
inlet funnel
outlet flask (Receiver)
Conditions d'expédition
ambient
Description générale
Les dispositifs de filtration stérilisante Stericup® et Steritop® utilisent des membranes fiables et hautement performantes pour une filtration stérilisante optimale des réactifs, tampons et milieux de laboratoire. Ces dispositifs associent des débits et des volumes filtrés supérieurs à une faible liaison non spécifique et à une conception stable et évitant tout basculement.
Cette unité de filtration à membrane en polyéthersulfone (PES) Stericup® de 0,22 µm de dimension de pores associe une unité de filtration pour flacon de 500 ml avec un flacon de réception de 1 000 ml et un bouchon pour le traitement et le stockage.
Application
- Milieux de culture cellulaire ± additifs
- Tampons
- Solutions biologiques
Caractéristiques et avantages
- Le du filtre Quick Release se déconnecte du flacon de réception en un quart de tour, ce qui réduit le risque de déversement et facilite la manipulation sur la paillasse ou sous la hotte.
- L'identification en gras du produit sur l'entonnoir Steritop® affiche clairement les caractéristiques de la membrane, notamment la composition et la taille des pores, pour une sélection rapide du produit adapté à l'application.
- Le bouchon à fermeture par clic est muni d'une collerette et est modifié pour assurer une prise en main sûre aussi bien en conditions humides que sèches et une butée tactile confirme la fermeture sécurisée. Ne vous inquiétez pas du risque de déversement ou de contamination du contenu stérilisé.
- Une large zone d'écriture dépolie sur le flacon de réception et la couleur plus claire du bouchon permettent un étiquetage clair pour améliorer la lisibilité et réduire les bavures illisibles.
- Le bouchon à fermeture par clic repose sur le côté pour éviter tout risque de contamination.
- Les flacons de réception sont empilables pour gagner de l'espace de stockage.
Informations légales
Vous ne trouvez pas le bon produit ?
Essayez notre Outil de sélection de produits.
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Articles
Evaluation of sterile filtration devices for protein preservation in sterile filtration of cell culture media.
Contenu apparenté
This article shows that a PES membrane containing Stericup Quick Release filter provides an alternative for the pluripotent expansion of embryonic stem cells.
-
Can Stericup® and Steritop® filters be reused?
1 answer-
Helpful?
-
-
What is the chemical compatibility of the various Stericup® and Steritop® filters?
1 answer-
Please refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf
Helpful?
-
-
What leachables are detected during filtration processes using Stericup® filters?
1 answer-
We have not performed extractables/leachables studies for our Stericup® filters.
Helpful?
-
-
What Bacterial Endotoxins Test is used?
1 answer-
The test method used complies with USP 85 and EP 2.6.14 to ensure the absence of endotoxin in our products.
Helpful?
-
-
What is the difference between classic Stericup® filters and Stericup® “Quick Release” filters?
1 answer-
Stericup® Quick Release, or “QR”, filters feature a connection between funnel filter and receiver bottle that requires only a quarter-turn release to facilitate funnel removal. These filters come fully engaged – there is no need to tighten before use. The receiver bottle cap has flanges on the top surface to improve grip, as well as a positive lock stop to ensure a leak-proof seal with the receiver bottle. Other improvements include a large, frosted writing surface on the receiver bottle and a lighter cap color to facilitate labelling, more prominent volume markings on the filtration funnel and receiver bottle, and a product label with a peel-off lot record strip on the bag for easy viewing in storage.
Helpful?
-
-
What tubing can be used with Stericup® and Steritop® vacuum filters?
1 answer-
Stericup® and Steritop® filters are fitted with a 1/4” tube adapter. We recommend 3/16 in. (4.8 mm) ID silicone tubing to fit this tube adapter: https://www.sigmaaldrich.com/product/mm/xx7100004
Helpful?
-
-
Which type of pump should be used with Stericup® and Steritop® vacuum filters?
1 answer-
We recommend our Chemical Duty Pump: https://www.sigmaaldrich.com/product/mm/wp6111560
Helpful?
-
-
Are Stericup® and Steritop® filters GMP-certified?
1 answer-
No, Stericup® and Steritop® devices are not GMP-approved.
Helpful?
-
-
Can Stericup® and Steritop® filters be used to prepare solutions that will be administered to patients?
1 answer-
No, all Stericup® and Steritop® devices are Research Use Only.
Helpful?
-
-
Can Stericup® bottles be placed inside freezers for long-term storage of media?
1 answer-
You can successfully freeze and store many aqueous solutions (such as culture media) in Stericup® bottles at temperatures up to -20 °C (-4 °F). It is strongly recommended that you run a sample stability trial under your actual storage conditions prior to using Stericup® bottles for frozen storage.
Helpful?
-
Active Filters
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique