If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf
Wichtige Dokumente
MAK307
Malachite Green Phosphate Assay Kit
sufficient for 2500 colorimetric tests
Synonym(e):
Phosphate Determination Assay Kit
Größe auswählen
About This Item
Empfohlene Produkte
Verwendung
sufficient for 2,500 colorimetric tests
Nachweisverfahren
colorimetric
Relevante Krankheit(en)
cardiovascular diseases; gastrointestinal diseases
Lagertemp.
2-8°C
Verwandte Kategorien
Allgemeine Beschreibung
Anwendung
- Phosphatase Assays: liberation of phosphate from peptide, protein, or small molecule substrate.[1][3]
- Lipase Assays: liberation of phosphate from phospholipids
- Nucleoside Triphosphatase Assays: liberation of phosphate from nucleoside triphosphates (ATP, GTP, TTP, CTP etc).
- Quantitation of phosphate in phospholipids, proteins and DNAs, etc.
- Drug Discovery: high-throughput screen for phosphatase inhibitors.
Leistungsmerkmale und Vorteile
Eignung
Prinzip
Signalwort
Warning
H-Sätze
Gefahreneinstufungen
Eye Irrit. 2 - Flam. Liq. 3 - Met. Corr. 1 - Skin Irrit. 2
Lagerklassenschlüssel
3 - Flammable liquids
Flammpunkt (°F)
82.4 °F
Flammpunkt (°C)
28 °C
Hier finden Sie alle aktuellen Versionen:
Analysenzertifikate (COA)
Die passende Version wird nicht angezeigt?
Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Kunden haben sich ebenfalls angesehen
-
How can I determine the shelf life / expiration / retest date of this product?
1 answer-
Helpful?
-
-
Is this kit able to detect pyrophosphate too?
1 answer-
This kit is intended for the detection of free orthophosphate and has not been tested for pyrophosphate detection. There are other products available that are specifically for use in pyrophosphate detection. Please see the links below to review each item:
MAK168, Pyrophosphate Assay Kit
https://www.sigmaaldrich.com/product/sigma/mak168
MAK169. High Sensitivity Pyrophosphate Assay Kit
https://www.sigmaaldrich.com/product/sigma/mak169Helpful?
-
-
Does the product MAK307 contain magnesium?
1 answer-
Magnesium is not included as a component in any of the reagents provided with the kit for product MAK307. If magnesium serves as an essential cofactor for the enzyme, it is recommended to supplement it in the buffer before conducting the phosphate determination assay.
Helpful?
-
-
What are the reasons behind the suggestion to use lower concentrations than 0.25mM? Are there potential unwanted biochemical reactions between GTP and malachite green/molybdate if GTP concentration exceeds 0.25mM?
1 answer-
The kit operates by releasing free orthophosphate from ATP or GTP, followed by the creation of a green complex involving the orthophosphate, molybdate, and Malachite green. It has been observed that samples containing ATP and GTP at concentrations exceeding 0.25mM result in the measurement of free phosphate levels falling outside the detection range of the kit (0.02 µM and 40 µM phosphate), and hence should be avoided.
Helpful?
-
-
Why is it necessary to dilute the ATP concentration to <0.25 mM before the assay? Does ATP interfere with the assay?
1 answer-
BioAssay Support recommends reducing the ATP concentration before the assay to minimize background interference resulting from non-enzymatic ATP hydrolysis and to decrease the likelihood of reagent precipitation with unhydrolyzed ATP.
Helpful?
-
-
our kit expired, when I used to measure extracted polyphosphate degraded by the enzyme, the results were so different compared to the precious ones (when the kit was not expired), this means the result was not reliable after it expired?
1 answer-
Correct, products used beyond the expiration date will likely offer poor results.
Helpful?
-
-
Does Malachite Green interact with glycerol?
1 answer-
The Malachite Green Phosphate Assay Kit is based on the quantification of the green complex formed between Malachite Green, molybdate, and free orthophosphate. No specific compatibility study has been done with this kit and glycerol. This would need to be tested empirically, in a sample with a known phosphate concentration, with and without glycerol at the desired concentration.
Helpful?
-
-
Can we test the same MG in shrimp matrix ?
1 answer-
This product is suitable for a variety of sample types. There is no reason to suspect a problem with shrimp matrix. Attention should be given to sample preparation, handling, and dilution. See the link below to review the product datasheet which includes the protocol and troubleshooting tips:
https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/171/212/mak307bul.pdfHelpful?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
0 answers
Active Filters
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.