Produktname
Pellicon® XL-Kassette mit Ultracel® Membran, Chemistry: Composite Regenerated Cellulose (CRC) Screen Type: C Device Size: 50 cm²
Quality Segment
material
composite regenerated cellulose (CRC) membrane, polypropylene , polypropylene screen
feature
holdup volume 3.2 mL
manufacturer/tradename
Pellicon®
parameter
0.03–0.05 L/min recirculation rate, 15 mL min. working volume, 2.8 bar max. transmembrane pressure (40 psig), 5.5 bar max. inlet pressure (80 psi) at 50 °C
technique(s)
analytical sample preparation: suitable, protein purification: suitable
L
18.8 cm (7.4 in.)
W
3 cm (1.2 in.)
filtration area
50 cm2
membrane nominal area
50 cm2
gravimetric extractables
≤7.5 mg/device
matrix
Ultracel®
pore size
1000 kDa NMWCO
pH
2 –12
shipped in
ambient
General description
Features and Benefits
Analysis Note
Legal Information
1 of 1
Dieser Artikel | |||
|---|---|---|---|
| description Chemistry: Composite Regenerated Cellulose (CRC) Screen Type: C Device Size: 50 cm² | description Chemistry: Composite Regenerated Cellulose (CRC) Screen Type: C Device Size: 50 cm² | description Chemistry: Composite Regenerated Cellulose (CRC) Screen Type: C Device Size: 50 cm² | description Chemistry: Composite Regenerated Cellulose (CRC) Screen Type: C Device Size: 50 cm² |
| pore size 1000 kDa NMWCO | pore size 5 kDa NMWCO | pore size 30 kDa NMWCO | pore size 100 kDa pore size |
| technique(s) protein purification: suitable, analytical sample preparation: suitable | technique(s) protein purification: suitable, analytical sample preparation: suitable | technique(s) analytical sample preparation: suitable, protein purification: suitable | technique(s) protein purification: suitable, tangential flow filtration (TFF): suitable (analytical sample preparation) |
| filtration area 50 cm2 | filtration area 50 cm2 | filtration area 50 cm2 | filtration area 50 cm2 |
| matrix Ultracel® | matrix Ultracel® | matrix Ultracel® | matrix Ultracel® |
| material polypropylene screen, composite regenerated cellulose (CRC) membrane | material composite regenerated cellulose (CRC) membrane, polypropylene , polypropylene screen | material polypropylene screen, composite regenerated cellulose (CRC) membrane | material polypropylene screen ((permeate)), polypropylene housing, polypropylene screen ((feed)), composite regenerated cellulose (CRC) membrane |
| parameter 2.8 bar max. transmembrane pressure (40 psig), 15 mL min. working volume, 5.5 bar max. inlet pressure (80 psi) at 50 °C, 0.03–0.05 L/min recirculation rate | parameter 2.8 bar max. transmembrane pressure (40 psig), 0.03-0.05 L/min recirculation rate, 15 mL min. working volume, 5.5 bar max. inlet pressure (80 psi) at 50 °C | parameter 2.8 bar max. transmembrane pressure (40 psig), 0.03–0.05 L/min recirculation rate, 5.5 bar max. inlet pressure (80 psi) at 50 °C, 15 mL min. working volume | parameter - |
Still not finding the right product?
Explore all of our products under Pellicon® XL-Kassette mit Ultracel® Membran
Lagerklasse
12 - Non Combustible Liquids
flash_point_f
Not applicable
flash_point_c
Not applicable
wgk
WGK 2
Zulassungslistungen
Zulassungslistungen werden hauptsächlich für chemische Produkte erstellt. Für nicht-chemische Produkte können hier nur begrenzte Angaben gemacht werden. Kein Eintrag bedeutet, dass keine der Komponenten gelistet ist. Es liegt in der Verantwortung des Benutzers, die sichere und legale Verwendung des Produkts zu gewährleisten.