While most HPLC columns feature 10.32 threaded end fittings, some may have different types and sizes of fittings. Given the wide variety of HPLC systems, it is not possible to guarantee with complete certainty that a specific HPLC system utilizes 10.32 fittings. Furthermore, even within a single type of fitting, such as 10.32, there are short, standard, and extended versions of the nut and ferrule. Hence, it is advisable to consult the instrument manual to determine the correct fitting type and size.
Größe auswählen
| Ihnen/SKU | Verfügbarkeit | Preis |
|---|---|---|
1 unit | Warenkorb auf Verfügbarkeit prüfen | € 764,00 |
Über diesen Artikel
€ 764,00
Produktname
Purospher® STAR NH2 (5 µm), L × I.D. 150 mm x 4.6 mm LiChroCART™ HPLC cartridge, manuCART™ holder required for use
material
stainless steel column
Quality Segment
agency
suitable for USP L8
product line
Purospher®
feature
endcapped: no
packaging
1 ea of
extent of labeling
3.5% Carbon loading
parameter
250 bar pressure, 60 °C max. temp.
technique(s)
HPLC: suitable, LC/MS: suitable, mass spectrometry (MS): suitable (Low - Medium)
column L × I.D.
15 cm × 4.6 mm
surface area
330 m2/g
matrix
fully porous particle
matrix active group
NH2, NH2 bonding phase
particle size
5 μm
pore size
120 Å pore size
operating pH range
2-7.5
separation technique
hydrophilic interaction (HILIC), normal phase, reversed phase
storage temp.
no temp limit
General description
Application
Features and Benefits
- Ultra-pure silica (99.999%)
- Low silanol activity
- Reproducible results from run-to-run and batch-to-batch
Analysis Note
Theoretical Plates (N/m) (2-Nitrotoluene): ≥ 50000
Symmetry (2-Nitrotoluene): 0.8 - 1.4
Capacity factor (2-Nitrotoluene): ≤ 3.0
Legal Information
1 of 1
Dieser Artikel | |||
|---|---|---|---|
| description L × I.D. 150 mm x 4.6 mm LiChroCART™ HPLC cartridge, manuCART™ holder required for use | description L × I.D. 250 mm x 4 mm LiChroCART™ HPLC cartridge, manuCART™ holder required for use | description L × I.D. 125 mm x 4 mm LiChroCART™ HPLC cartridge, manuCART™ holder required for use | description L × I.D. 250 mm x 4.6 mm LiChroCART™ HPLC cartridge, manuCART™ holder required for use |
| matrix active group NH2, NH2 bonding phase | matrix active group NH2, NH2 bonding phase | matrix active group NH2, NH2 bonding phase | matrix active group NH2, NH2 bonding phase |
| separation technique hydrophilic interaction (HILIC), reversed phase, normal phase | separation technique hydrophilic interaction (HILIC), normal phase, reversed phase | separation technique hydrophilic interaction (HILIC), normal phase, reversed phase | separation technique hydrophilic interaction (HILIC), normal phase, reversed phase |
| particle size 5 μm | particle size 5 μm | particle size 5 μm | particle size 5 μm |
| technique(s) HPLC: suitable, mass spectrometry (MS): suitable (Low - Medium), LC/MS: suitable | technique(s) HPLC: suitable, LC/MS: suitable, mass spectrometry (MS): suitable (Low - Medium) | technique(s) HPLC: suitable, LC/MS: suitable, mass spectrometry (MS): suitable (Low - Medium) | technique(s) HPLC: suitable, LC/MS: suitable, mass spectrometry (MS): suitable (Low - Medium) |
| agency suitable for USP L8 | agency suitable for USP L8 | agency suitable for USP L8 | agency suitable for USP L8 |
| pore size 120 Å pore size | pore size 120 Å pore size | pore size 120 Å pore size | pore size 120 Å pore size |
Still not finding the right product?
Explore all of our products under Purospher® STAR NH2 (5 µm)
Hier finden Sie alle aktuellen Versionen:
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
-
Is the product Purospher® STAR NH2 (5 µm) LiChroCART® 150-4.6 column (catalog number 1.50247.0001 or 48219-474) compatible with the Agilent 1260 HPLC system?
1 answer-
Helpful?
-