LC/MS Extracted Ion Chromatogram of MSX, Sulfone, and Sulfoxide on Ascentis® Express OH5 (HILIC Mode)

LC/MS Extracted Ion Chromatogram of MSX, Sulfone, and Sulfoxide on Ascentis® Express OH5 (HILIC Mode) application for HPLC

Materiales

analytical column

Referencia del producto
Descripción
Precios

Ascentis® Express OH5, 2.7 μm HPLC Column

2.7 μm particle size, L × I.D. 10 cm × 3 mm

standard

Referencia del producto
Descripción
Precios

L-metionina sulfoximina

suitable for cell culture

CONDITIONS

column

Ascentis Express OH5, 10 cm x 3 mm I.D., 2.7 μm particles (53769-U)

mobile phase

[A] 0.1% formic acid, pH 3.5 with ammonium formate; [B] acetonitrile; (25:75, A:B)

flow rate

0.4 mL/min

pressure

1350 psi (93 bar)

column temp.

ambient

detector

ESI (+), scan m/z 150-300

injection

5 μL

sample

10 μg/mL in 90% methanol

Descripción

Analysis Note

This figure shows the extracted ion currents for methionine sulfoximine-related compounds on Ascentis Express OH5. The OH5 shows excellent peak shape compared to traditional HILIC on bare silica.