F8763

Supelco

Flunitrazepam solution

drug standard, 1.0 mg/mL in methanol

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula empírica (notación de Hill):
C16H12FN3O3
Número de CAS:
Peso molecular:
313.28
EC Number:
MDL number:
UNSPSC Code:
41116107
PubChem Substance ID:

grade

drug standard

assay

≥98%

drug control

Home Office Schedule 3; psychotrope (France); kontrollierte Droge in Deutschland; regulated under CDSA - not available from Sigma-Aldrich Canada

concentration

1.0 mg/mL in methanol

technique(s)

HPLC: suitable
gas chromatography (GC): suitable

application(s)

pharmaceutical (small molecule)

format

single component solution

storage temp.

2-8°C

SMILES string

CN(C1=CC=C([N+]([O-])=O)C=C1C(C2=CC=CC=C2F)=NC3)C3=O

InChI

1S/C16H12FN3O3/c1-19-14-7-6-10(20(22)23)8-12(14)16(18-9-15(19)21)11-4-2-3-5-13(11)17/h2-8H,9H2,1H3

InChI key

PPTYJKAXVCCBDU-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Application

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

comparable product

Referencia del producto
Descripción
Precios

signalword

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

target_organs

Eyes

Storage Class

3 - Flammable liquids

wgk_germany

WGK 2

flash_point_f

51.8 °F - closed cup

flash_point_c

11 °C - closed cup

ppe

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Paul D'Aloise et al.
Science & justice : journal of the Forensic Science Society, 52(1), 2-8 (2012-02-14)
Desorption electrospray ionization-mass spectrometry (DESI-MS), a novel ambient ionization technique, was used in this study for determining flunitrazepam in various alcoholic beverages. Using this technique, no pretreatment of the samples was necessary and identification of the drug was accomplished in
M A Mattila et al.
Drugs, 20(5), 353-374 (1980-11-01)
Flunitrazepam is a benzodiazepine derivative whose hypnotic effect predominates over the sedative, anxiolytic, muscle-relaxing and anticonvulsant effects characteristic of benzodiazepines. Thus, it is used as a night-time hypnotic and in anaesthesiology: due to the pronounced hypnotic effect it is not
Vanessa Pauly et al.
International clinical psychopharmacology, 26(5), 268-277 (2011-08-11)
Fourteen benzodiazepine (BZD) or BZD-like medications were analyzed with three data sources aiming to assess prescription drug abuse for the year 2008. After a descriptive analysis, a principal component analysis was carried out to explore correlations between seven indicators obtained
T Suzuki et al.
Endoscopy, 44(1), 38-42 (2011-12-07)
Studies have estimated that failure of cecal intubation occurs with conventional colonoscopy in up to 10 % of cases. Double-balloon endoscopy (DBE) systems, magnetic endoscope imaging (MEI), and transparent cap have been shown to improve success rates for colonoscopy. This study
Lisa R Gerak et al.
The Journal of pharmacology and experimental therapeutics, 340(3), 742-749 (2011-12-17)
Adverse effects of benzodiazepines limit their clinical use; these effects might be reduced without altering therapeutic effects by administering other positive GABA(A) modulators (i.e., neuroactive steroids) with benzodiazepines. One concern with this strategy involves reversing these combined effects in case

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico