Supelco

Amberlite XAD®-2

pkg of 500 g

Sign Into View Organizational & Contract Pricing


About This Item

CAS Number:
UNSPSC Code:
23151817
Pricing and availability is not currently available.

form

beads (small)

Quality Level

packaging

pkg of 500 g

availability

not available in (Currently experiencing backorder delays due to raw material supply disruption)

technique(s)

HPLC: suitable
LPLC: suitable

surface area

~300 m2/g

matrix

styrene-divinylbenzene (macroreticular)

matrix active group

polymer

particle size

20-60 mesh

pore size

~0.65 mL/g pore volume
90 Å mean pore size

density

1.02 g/mL at 25 °C (true wet)(lit.)
1.08 g/mL at 25 °C (skeletal)(lit.)

separation technique

reversed phase

storage temp.

2-8°C

InChI

1S/C24H27NO5/c1-24(2,3)30-22(27)13-12-16(14-26)25-23(28)29-15-21-19-10-6-4-8-17(19)18-9-5-7-11-20(18)21/h4-11,14,16,21H,12-13,15H2,1-3H3,(H,25,28)/t16-/m0/s1

InChI key

BCIPGSZQUDLGSY-INIZCTEOSA-N

Looking for similar products? Visit Product Comparison Guide

General description

Amberlite XAD-2, a hydrophobic copolymer of styrene-divinylbenzene resin, requires longer purification process and is used as a sorbent. Amberlite XAD-2 resin depending upon the aromaticity and size of the hydrophobic groups sorbs organic compounds through low-energy physical interactions.[1]
Nonionic macroreticular resin that adsorbs and releases ionic species through hydrophobic and polar interactions; usually used under isocratic conditions.
Specifications:

Application

Amberlite XAD®-2 was used:
  • as adsorbent in the extraction of organochlorine compounds using Soxhlat extraction technique[1]
  • as adsorbent in the extraction of honey samples using column chromatography for HPLC analysis[2]
  • in adsorption chromatography[3]
Polyaromatic adsorbent resin for hydrophobic compounds up to MW 20,000: phenols, organic removal, surfactants, aroma compounds, antibiotic recovery. May be used as support for catalyst or metals removal. For cleaned US EPA versions, see Supelpak-2 and Supelpak-2B.
     

Legal Information

Amberlite is a trademark of DuPont de Nemours, Inc.
XAD is a registered trademark of The Dow Chemical Company or an affiliated company of Dow

related product

Product No.
Description
Pricing

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable

Personal Protective Equipment

dust mask type N95 (US), Eyeshields, Gloves

Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

M Tamura et al.
The Journal of biological chemistry, 260(17), 9672-9677 (1985-08-15)
Na+,K+-ATPase inhibitors have been found to exist in acutely saline-infused hog plasma, which also inhibit the specific binding of ouabain to Na+,K+-ATPase and the binding of digoxin to specific anti-digoxin antibody. Two of these inhibitors were purified by a combination
Trapping efficiency of polyurethane foam and Amberlite XAD-2 for various organochlorine compounds
Nerin, C., et al.
Fresenius Journal of Analytical Chemistry, 352, 609-611 (1995)
I Martos et al.
Journal of agricultural and food chemistry, 48(5), 1498-1502 (2000-05-23)
European Eucalyptus honeys showed a common and characteristic HPLC profile in which the flavonoids myricetin (3,5,7,3',4', 5'-hexahydroxyflavone), tricetin (5,7,3',4',5'-pentahydroxyflavone), quercetin (3,5,7,3',4'-pentahydroxyflavone), luteolin (5,7,3', 4'-tetrahydroxyflavone), and kaempferol (3,5,7, 4'-tetrahydroxyflavone) were identified. Their contents, and relative amounts, in the analyzed honey samples
Mario Vincenzo Russo et al.
Analytical and bioanalytical chemistry, 404(5), 1517-1527 (2012-07-05)
This paper shows an analytical methodology based on solid-phase extraction by XAD-2 adsorbent and gas chromatography (GC) coupled with nitrogen-phosphorus (NPD) and ion-trap mass spectrometry detectors (ITMS) in negative chemical ionization (NCI) mode analyses for investigating organophosphorus pesticides (OPs) at
Feng Xiao et al.
Journal of colloid and interface science, 368(1), 505-511 (2011-12-14)
Amberlite XAD resins have been employed to a great extent as the sorbent for removing or concentrating organic compounds from different matrices. We present for the first time a systematic study on the sorption of perfluorochemical (PFC) surfactants, an emerging

Related Content

Low pressure liquid chromatography (LPLC) operates at low pressures, using a pump to drive the mobile phase onto the column.

FAS, or 'forever chemicals,' persist in the environment and pose risks to human health. Discover our environmental monitoring tools for PFAS quantification, aiding researchers, regulators, and labs in testing for PFAS.

Questions

1–7 of 7 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. What is the most approriate protocol to wash Amberlite before use? Thanks in advance!

    1 answer
    1. Amberlite XAD-2 is a crude preparation and must be thoroughly cleaned prior to use.

      1. Rinse with hot deionized water (may hold in nylon filter cloth to retain particles) - use at least 3 bed volumes per hour at 110 deg C
      2. Soak overnight in 2 bed volumes (BV) of ethanol.
      3. Load resin into a glass column and rinsed with a further 2 BV of ethanol.
      4. Rinse with 2 BV of deionized water to remove the ethanol, 1 BV of 4% (w/v) sodium hydroxide, 2 BV of deionized water, 1 BV 4% (v/v) hydrochloric acid, and finally rinse with deionized water until the pH of the eluent is neutral.

      For further use it is advantageous to do a wash in the same solvent use in the application.
      Store in sealed container; may be refrigerated but NOT frozen. As a bacteriostat, one may rinse with 20% ethanol (deionized water) prior to storage.

      Helpful?

  4. Is Amberlite XAD-2 ready-to-use?

    1 answer
    1. No.  Amberlite XAD2 is shipped imbibed with 5% NaCl & 1% NaCO3; it has not been specially processed nor cleaned. We suggest that it be extensively treated to a suitable preliminary elution and wash.

      Helpful?

  5. May I purchase Amberlite XAD-2 in large quantities?

    1 answer
    1. The largest package size of Amberlite XAD2 is 25 kg (Product No. 3025-U).

      Helpful?

  6. Do you offer a precleaned Amberlite XAD-2?

    1 answer
    1. Yes.  Supelco cleans Amberlite XAD2 for a variety of environmental applications.

      Helpful?

  7. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service