Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
55460
Hydroxylamine hydrochloride
puriss. p.a., ACS reagent, ≥99.0% (RT)
Synonym(s):
Hydroxylammonium chloride
About This Item
Recommended Products
grade
ACS reagent
puriss. p.a.
Quality Level
vapor pressure
0.001 hPa ( 50 °C)
Assay
≥99.0% (RT)
form
powder or crystals
technique(s)
inhibition assay: suitable
ign. residue
≤0.05% (as SO4)
pH
2.5-3.5 (25 °C, 50 mg/mL in H2O)
mp
155-157 °C (dec.) (lit.)
density
1.67 g/mL at 25 °C (lit.)
anion traces
sulfate (SO42-): ≤50 mg/kg
cation traces
Ca: ≤10 mg/kg
Cd: ≤5 mg/kg
Co: ≤5 mg/kg
Cr: ≤5 mg/kg
Cu: ≤5 mg/kg
Fe: ≤5 mg/kg
K: ≤50 mg/kg
Mg: ≤5 mg/kg
Mn: ≤5 mg/kg
Na: ≤50 mg/kg
Ni: ≤5 mg/kg
Pb: ≤5 mg/kg
Zn: ≤5 mg/kg
heavy metals: ≤5 ppm (by ICP)
SMILES string
Cl.NO
InChI
1S/ClH.H3NO/c;1-2/h1H;2H,1H2
InChI key
WTDHULULXKLSOZ-UHFFFAOYSA-N
Looking for similar products? Visit Product Comparison Guide
Related Categories
General description
Application
- Mass Spectrometry-Based Atlas of Extracellular Matrix Proteins across 25 Mouse Organs.: This study utilized hydroxylamine hydrochloride in mass spectrometry to analyze the extracellular matrix proteins in various mouse organs, offering insights into tissue-specific protein compositions (McCabe et al., 2023).
- Analysis of extracellular metabolome by HS-SPME/GC-MS: Optimization and application in a pilot study to evaluate galactosamine-induced hepatotoxicity.: Hydroxylamine hydrochloride was employed in HS-SPME/GC-MS to optimize the analysis of extracellular metabolites, crucial for assessing hepatotoxic effects (Araújo et al., 2018).
- Improved production and processing of ⁸⁹Zr using a solution target.: This research enhanced the production process of zirconium-89 with hydroxylamine hydrochloride, improving efficiency and yield for medical imaging applications (Pandey et al., 2016).
- Evaluation of the physicochemical properties and the biocompatibility of polyethylene glycol-conjugated gold nanoparticles: A formulation strategy for siRNA delivery.: The study used hydroxylamine hydrochloride to modify gold nanoparticles, improving their biocompatibility and effectiveness in siRNA delivery systems (Rahme et al., 2015).
- Preparation and photocatalytic performance of Fe (III)-amidoximated PAN fiber complex for oxidative degradation of azo dye under visible light irradiation.: Hydroxylamine hydrochloride was used in the synthesis of Fe(III)-amidoximated PAN fibers, enhancing their photocatalytic degradation properties for environmental applications (Dong et al., 2010).
Biochem/physiol Actions
Signal Word
Warning
Hazard Statements
Precautionary Statements
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Oral - Aquatic Acute 1 - Aquatic Chronic 2 - Carc. 2 - Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2 - Skin Sens. 1 - STOT RE 2 Oral
Target Organs
spleen
Storage Class Code
4.1A - Other explosive hazardous materials
WGK
WGK 3
Flash Point(F)
Not applicable
Flash Point(C)
Not applicable
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Customers Also Viewed
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 answer-
Helpful?
-
-
How can I determine the shelf life / expiration / retest date of this product?
1 answer-
If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdfHelpful?
-
Active Filters
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service