FHIFI-RO
Roche
FastStart™ High Fidelity PCR System
5 unit/μL, suitable for PCR, High Fidelity PCR, hotstart, Multiplex PCR
About This Item
Recommended Products
usage
sufficient for ≤1,000 reactions (03553361001)
sufficient for ≤200 reactions (03553400001)
Quality Level
feature
High Fidelity PCR
Multiplex PCR
dNTPs included: no
hotstart
packaging
pkg of 2,500 U (03553361001 [10 x 250 U])
pkg of 500 U (03553400001 [2 x 250 U])
manufacturer/tradename
Roche
concentration
5 unit/μL
parameter
72 °C optimum reaction temp.
technique(s)
PCR: suitable
input
purified DNA
storage temp.
−20°C
Related Categories
General description
Hot start protocols have improved specificity, sensitivity, and PCR yield. Heat-labile blocking groups on amino acid residues of FastStart™ Taq DNA Polymerase make the enzyme inactive at room temperature. There is no elongation at low temperatures when primers bind nonspecifically. FastStart™ Taq DNA Polymerase is activated by removal of blocking groups using a preincubation step at +95°C. The FastStart™ High Fidelity PCR System is the product of choice for multiplex PCR.
- FastStart™ High Fidelity Enzyme Blend, (5 U/μl) in storage buffer
- FastStart™ High Fidelity Reaction Buffer, 10x concentrated, with 18 mM MgCl2
- FastStart™ High Fidelity Reaction Buffer, 10x concentrated, without MgCl2
- MgCl2 Stock Solution, 25 mM
- DMSO
Application
- PCR
- Multiplex PCR
- RT-PCR
- GC-rich template amplification
- Difficult or challenging PCRs
- in the amplification of Human Papillomaviral genome and methylated DNA
The FastStart™ High Fidelity PCR System is the product of choice for multiplex PCR.
Use FastStart™ High Fidelity PCR System, dNTPack with ready-to-use PCR Nucleotide Mix.
Features and Benefits
- Achieve excellent multiplex performance.
- For fast high quality results, also use Roche′s PCR Optimization Kit.
- Increase fidelity.
- Achieve fourfold higher fidelity compared to Taq DNA Polymerase and FastStart Taq DNA Polymerase.
- Amplify challenging DNA.
- DMSO, a PCR additive, for working with difficult templates, is supplied.
Packaging
Quality
Unit Definition
Volume Activity: 5 U/μl
Preparation Note
Other Notes
Legal Information
Kit Components Only
- FastStart High Fidelity Enzyme Blend, in storage buffer 5 U/μl
- FastStart High Fidelity Reaction Buffer, with 18 mM MgCl2 10x concentrated
- FastStart High Fidelity Reaction Buffer, without MgCl2 10x concentrated
- MgCl2 Stock Solution 25 mM
- DMSO
Storage Class
10 - Combustible liquids
wgk_germany
WGK 1
flash_point_f
203.0 °F
flash_point_c
95 °C
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Customers Also Viewed
Articles
The purpose of Hot Start PCR is to inhibit the PCR reaction in order to reduce nonspecific amplification, prevent the formation of primer dimers, and increase product yields.
Identify causes and remedies for SDS-PAGE sample preparation challenges and optimize electrophoresis conditions.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service