Recommended Products
assay
98%
form
liquid
refractive index
n20/D 1.5077 (lit.)
bp
155 °C/15 mmHg (lit.)
mp
17 °C (lit.)
density
0.946 g/mL at 25 °C (lit.)
SMILES string
CCCCCCC(=O)c1ccccc1
InChI
1S/C13H18O/c1-2-3-4-8-11-13(14)12-9-6-5-7-10-12/h5-7,9-10H,2-4,8,11H2,1H3
InChI key
UXMQORVHJMUQFD-UHFFFAOYSA-N
General description
Heptanophenone is an alkyl phenyl ketone and its inhibitory effect on carbonyl reductase activity in pig heart has been examined.
Application
Heptanophenone was employed as test compound to compare the kinetic performance of monolithic and fused-core capillary C(18) columns in isocratic-elution liquid chromatography.
Storage Class
10 - Combustible liquids
wgk_germany
WGK 3
flash_point_f
235.4 °F - closed cup
flash_point_c
113 °C - closed cup
ppe
Eyeshields, Gloves, type ABEK (EN14387) respirator filter
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Journal of chromatography. A, 1523, 224-233 (2017-06-18)
The present paper discusses practical aspects of prototyping of microfluidic chips using cyclic olefin copolymer as substrate and the application in high-performance liquid chromatography. The developed chips feature a 60mm long straight separation channel with circular cross section (500μm i.d.)
Journal of chromatography. A, 1261, 107-112 (2012-09-12)
The kinetic performance of monolithic and fused-core capillary C(18) columns was compared in isocratic-elution liquid chromatography. Heptanophenone was chosen as a test compound. The (u(0), H) couple obtained in a column with permeability K(v0) was transferred into a plate number
The Analyst, 144(5), 1809-1817 (2019-01-24)
The performance of a porous-layered radially elongated pillar (PLREP) array column in a commercial nano-LC system was examined by performing separation of alkylphenones and peptides. The mesoporous silica layer was prepared by sol-gel processing of a mixture of tetramethoxysilane and
Journal of chromatography. A, 1626, 461279-461279 (2020-08-17)
We report on a comparative study of the basic separation kinetics of commercial packed bed columns and a micro-pillar array column (μPAC) working in the 1-10μL/min flow rate range, i.e., operating in the area of capillary flow LC. This is
Journal of chromatography. A, 1598, 132-140 (2019-04-15)
Stationary phases that can withstand extremes of pH and temperature are needed to allow a single column to accommodate a wider set of solutes and separation criteria. We used a simple multi-step process using the thiol-yne reaction following the modification
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service