GE28-9269-88
HiScreen™ pHenyl Fast Flow, High Sub
Cytiva 28-9269-88
About This Item
Recommended Products
ligand
phenyl
form
prepacked column
crosslinking
cross-linked
packaging
pkg of 1 ea
manufacturer/tradename
Cytiva 28-9269-88
storage condition
(20% Ethanol)
parameter
1.5 bar (22 psi) (Over the Packed Bed During Operation)
22 psi
technique(s)
liquid chromatography (LC): suitable
bed size
7.7 mm × 100 mm
bed volume
4.7 mL
column I.D.
7.7 mm
matrix
6% cross-linked agarose
matrix active group
phenyl functional group
particle size
45-165 μm
average diameter
90 μm
cleaning
2-14
working range
3-13
suitability
suitable for bioprocess medium
separation technique
hydrophobic interaction (HIC)
Storage temp.
2-8°C
General description
The small column volume of 4.7 mL and bed height of 10 cm make HiScreen columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up. Process fluid velocities can be applied, since the 10 cm bed height gives enough residence time and the results can then serve as basis for linear process scale-up.
If necessary, two columns can easily be connected in series to give a bed height of 2NA cm.
Media prepacked in HiScreen HIC columns are also available in other formats and as bulk packs, which makes it possible to use the same media for development work, pilot studies, and routine production.
Features and Benefits
- Prepacked, ready-to-use columns for convenient process development optimization.
- 1NA cm bed height of HiScreen columns is designed to allow method optimization and parameter screening.
- Easily connected in series to achieve 2NA cm bed height.
- Small bed volume gives fast results and minimal sample/buffer consumption.
- Reproducible results, scalable to BioProcess columns packed with the same media using the same linear fluid velocity.
Storage and Stability
Analysis Note
Legal Information
related product
signalword
Warning
hcodes
Storage Class
3 - Flammable liquids
Choose from one of the most recent versions:
Certificates of Analysis (COA)
It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.
If you need assistance, please contact Customer Support
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service