GE17-1182-01
RESOURCE™ RPC
Cytiva 17-1182-01, pack of 3 mL
Sign Into View Organizational & Contract Pricing
All Photos(1)
About This Item
Recommended Products
ligand
matrix surface
feature
autoclavable 20 min at 121°C
packaging
pack of 3 mL
manufacturer/tradename
Cytiva 17-1182-01
parameter
580 psi
bed size
6.4 mm × 100 mm
bed volume
3 mL
matrix
polystyrene/divinylbenzene
avg. part. size
15 μm (monosized)
cleaning
1-14
working range
1-12
capacity
~10 mg binding capacity
suitability
suitable for bioprocess medium
General description
RESOURCE™ RPC are prepacked SOURCE™ 15RPC columns designed for rapid screening experiments, method development, and small-scale protein purification using reversed phase chromatography.
~10 mg BSA /ml medium at 300 cm/h, ~30 mg bacitracin/ml medium at 300 cm/h, ~50 mg insulin/ml medium at 300 cm/h
Application
SOURCE™ 15RPC is based on rigid, monosized 15 μm diameter polystyrene/divinyl benzene beads. The matrix has outstanding selectivity for RPC. The monodispersity of the beads yields stable beds, Low back pressures and excellent results at high flow rates.With its high physical and chemical stability and very high batch-to-batch reproducibility, SOURCE™ 15RPC is well suited for all stages of an industrial scale operation - from research and process development through scale-up and into production. SOURCE™ 15RPC offers properties superior to those of other polymeric matrices.
Features and Benefits
- Wide pH range (1-12), outstanding selectivity, chemical resistance, high capacity, and high resolution at high flow rates.
- Excellent scalability, from RESOURCE™ to FineLINE columns.
- Use RESOURCE™ RPC 3 mL column for higher resolution and method development on a 10 cm bed height.
Storage and Stability
Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (20% Ethanol or 70% Acetonitrile)
Analysis Note
To view the Certificate of Analysis for this product, please visit www.cytiva.com.
Other Notes
The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.
Legal Information
RESOURCE is a trademark of Cytiva
SOURCE is a trademark of Cytiva
signalword
Warning
hcodes
Storage Class
3 - Flammable liquids
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service