Accéder au contenu
Merck
Toutes les photos(1)

Principaux documents

48734

Supelco

Aroclor 1254 solution

certified reference material, 50 mg/kg in transformer oil

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Numéro CAS:
Numéro MDL:
Code UNSPSC :
12000000

Qualité

certified reference material
TraceCERT®

Niveau de qualité

Gamme de produits

TraceCERT®

CofA (certificat d'analyse)

current certificate can be downloaded

Conditionnement

ampule of 5 mL

Concentration

50 mg/kg in transformer oil

Technique(s)

HPLC: suitable
gas chromatography (GC): suitable

Application(s)

environmental

Format

single component solution

Température de stockage

2-30°C

Chaîne SMILES 

Clc1c(c(ccc1Cl)c2c(c(ccc2)Cl)Cl)Cl

InChI

1S/C12H5Cl5/c13-8-3-1-2-6(10(8)15)7-4-5-9(14)12(17)11(7)16/h1-5H

Clé InChI

AUGNBQPSMWGAJE-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Application

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Autres remarques

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Informations légales

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictogrammes

Health hazardEnvironment

Mention d'avertissement

Danger

Mentions de danger

Classification des risques

Aquatic Chronic 2 - Carc. 1B - STOT RE 2

Code de la classe de stockage

6.1C - Combustible, acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable

Équipement de protection individuelle

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

Si vous avez besoin d'assistance, veuillez contacter Service Clients

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Les clients ont également consulté

Slide 1 of 1

1 of 1

Hamdy A A Aly
Environmental toxicology and pharmacology, 36(2), 274-283 (2013-05-21)
Aroclor 1254, a commercial mixture of highly toxic environmental pollutant, is known to cause testicular toxicity. The present study was undertaken to delineate and elucidate the nature and the mechanism of action of Aroclor 1254 on rat sperm in vitro.
Jing An et al.
Toxicology, 295(1-3), 8-14 (2012-03-13)
Polychlorinated biphenyls (PCBs) are still prevalent in the environment despite the fact that they have been banned in many countries for several decades. Recent epidemiologic studies have demonstrated a link between PCBs exposure and pathological alterations of bone tissues. The
L A Martin et al.
Drug metabolism and disposition: the biological fate of chemicals, 40(3), 588-595 (2011-12-22)
Polychlorinated biphenyl (PCB) congeners differentially reduce serum thyroxine (T(4)) in rats, but little is known about their ability to affect biliary excretion of T(4). Thus, male Sprague-Dawley rats were orally administered Aroclor-1254, Aroclor-1242 (32 mg/kg per day), PCB-95, PCB-99, PCB-118
Lubna E Elabbas et al.
Toxicology letters, 207(1), 82-88 (2011-08-23)
Exposure to polychlorinated biphenyls (PCBs) induce a broad spectrum of toxic effects in various organs including bone. The most susceptible age-groups to the toxic effects of PCBs are foetuses and infants. The aim of the present study was to quantitatively
Sylvie Cotelle et al.
Environmental science and pollution research international, 19(3), 628-635 (2011-09-08)
Assessment of environmental impacts from pesticide utilization should include genotoxicity studies, where the possible effects of mutagenic/genotoxic substances on individuals are assessed. In this study, the genotoxicity profile of the new formicide Macex® was evaluated with two genotoxicity tests, namely

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique